background image

6

English

 

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

Children as well as adults with physical, mental and/

or sensoric impairments must not use this product 

without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from 

using this product.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• If the thermostat or mixer is set to maximum water 

temperature, there is a risk of scalding at hydraulical 

opening of the check valve. For this reason, 

Hansgrohe recommends that you set up the "Safety 

Function".

Special information for UK 

If installing this product with a pump, please be aware 

that it has to have negative head switching. This product 

will not function with a positive head pump.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

• Thermostat Highflow for 1 consumer (at the bottom) 

and one additional consumer (on top)

Symbol description

Do not use silicone containing acetic acid!

Installation example 

(see page 8)

Adjustment 

(see page 16)

After the installation, the output temperature of the 

thermostat must be checked. A correction is necessary if 

the temperature measured at the output differs from the 

temperature set on the thermostat.

Safety Function 

(see page 16)

The desired maximum temperature for example max. 

42º C can be pre-set thanks to the safety function.

Maintenance 

(see page 18)

• The check valves must be checked regularly 

according to EN 806-5 in accordance with national 

or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it 

is necessary from time to time to turn the thermostat 

from total hot to total cold.

Dimensions 

(see page 21)

Flow diagram 

(see page 21)

 

free flow

  Outlet 1

  Outlet 2

Spare parts 

(see page 22)

Special accessories 

(see page 22)

 

order as an extra

• extension 25 mm #13595000

• Extension Set 22 mm (when wall is not deep 

enough) #13593000

• levelling set 1° #95521000

• nut + flange #92696000

Cleaning 

(see page 23)

Operation 

(see page 20)

Minor leaking may occur briefly during initial commis-

sioning and interruption/restart of the water supply.

Test certificate 

(see page 23)

i

+

Summary of Contents for Picta Select 13752000

Page 1: ...DE Gebrauchsanleitung Montageanleitung 2 FR Mode d emploi Instructions de montage 4 EN Instructions for use assembly instructions 6 Picta Select 13752000 40 C...

Page 2: ...tion max 70 C 4 min Eigensicher gegen R ckflie en Das Produkt ist ausschlie lich f r Trinkwasser konzipiert Thermostat Highflow f r 1 Verbraucher unten und einen zus tzlichen Verbraucher oben Symboler...

Page 3: ...Regeleinheit verkalkt Regeleinheit austauschen Bei Neuinstallation Grundk rper falsch angeschlossen Soll kalt rechts warm links oder 180 verdreht eingebaut Funktionsblock um 180 verdreht einbauen Dru...

Page 4: ...PSI Temp rature d eau chaude max 70 C Temp rature recommand e 65 C D sinfection thermique max 70 C 4 min Avec dispositif anti retour Le produit est exclusivement con u pour de l eau potable Thermostat...

Page 5: ...tre droite et l eau chaude gauche ou elle est mont e l envers Montez le bloc de fonction 180 Bouton pression du verrouillage de s curit d fectueux Ressort d fectueux Bouton pression entartr Nettoyer...

Page 6: ...a 1 MPa 10 bar 147 PSI Hot water temperature max 70 C Recommended hot water temp 65 C Thermal disinfection max 70 C 4 min Safety against backflow The product is exclusively designed for drinking water...

Page 7: ...on not possible thermo cartridge calcified Exchange thermo cartridge For new installations basic body incorrectly connected should be cold right hot left or installed with 180 rotation Install functio...

Page 8: ...4000 verwendet werden 13752000 13754000 70 mm 50 l min Thermostat Highflow for 1 func tion 13752000 may only be used in combination with flush valve 3 functions 13754000 Thermostat Highflow pour 1 fon...

Page 9: ...9 SW 5 mm 2 1 2 1 01800180 SW 4 mm 5 Nm 2 3 SW 4 mm 1 1 2 mm 1 2 3 4 5 6...

Page 10: ...10 1 2 0 mm 0 mm 7 8 9...

Page 11: ...11 1 2 3 SW 4 mm 1 2 SW 10 mm 2 Nm X 1 2 mm Silicone 10 11 12 13 14...

Page 12: ...12 0 1 Nm 1 2 1 2 X 11 Silicone 15 16 17 18 19 20...

Page 13: ...13 40 C 40 C 2 1 40 C 1 2 40 C SW 3 mm 2 Nm 40 C CLICK 21 22 23 24 25 26...

Page 14: ...14 40 C 1 2 0 mm A 0 mm 40 C 40 C 40 C 27 A B C D E...

Page 15: ...15 0 SW 4 mm 5 Nm 40 C max 5 SW 4 mm 1 2 7 mm 28 C A B...

Page 16: ...16 40 C 2 1 1 2 40 C 40 C 40 C 1 2 3 SW 3 mm...

Page 17: ...17 40 C SW 3 mm 2 Nm 1 CLICK 40 C 2 1 7 8 5 6 2 z B 42 C for example 42 C 3 4 2 1...

Page 18: ...18 40 C SW 4 mm 40 C 2 1 2 3 4 5 6 SW 24 mm 1...

Page 19: ...19 SW 24 mm 15 Nm 40 C 40 C rot rouge red 7 8 0 1 Nm 9 10 11 12 CLICK 1 2 SW 4 mm 5 Nm...

Page 20: ...20 40 C 40 C 40 C 40 C 1 2 40 C schlie en ferm close ffnen ouvert open warm chaud hot kalt froid cold...

Page 21: ...2 0 4 0 6 0 8 1 0 Q l min Q l sec 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 155 155 53 102 48 69 97 20 73 155 155 1 2 40 C 2...

Page 22: ...1 5 SW 19 mm 92219000 98147000 26x2 98198000 38x2 5 98383000 34x2 96636000 98148000 43x1 5 96633000 SW 24 mm 96454000 M5x55 98793000 145 mm 97439000 92235000 96435000 SW 2 mm 98474000 92218000 9817400...

Page 23: ...ndation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w ax...

Page 24: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 09 2020 9 06622 01...