Assembly see page 31
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective, sedimentation
- Exchange cartridge
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
- Crossflow
- Exchange cartridge
Test certificate
(see page 36)
Spare parts
(see page 35)
XXX = Colors
000 = chrome plated
400 = white/chrome plated
820 = brushed nickel
Cleaning
see enclosed brochure.
Operation
(see page 36)
Flow diagram
(see page 32)
Dimensions
(see page 33)
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 35. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
English
4