4
Assembly see page 12
English
Cleaning
see enclosed brochure.
Test certificate
(see page 24)
Symbol description
Spare parts
(see page 20)
Do not use silicone containing acetic acid!
Adjustment
(see page 15)
To adjust the hot water limiter on single lever
mixers, please see page 15. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Operation
(see page 16)
Dimensions
(see page 18)
Flow diagram
(see page 18)
Maintenance
(see page 17)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Fault
Cause
Remedy
Insufficient water
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
check valve hasn't moved back
-
Exchange check valves
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Connections:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Safety against backflow
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
Summary of Contents for Metris Puro 31461000
Page 12: ...11 12...
Page 13: ...12 Montage 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm 31461000 32660000...
Page 14: ...13 Montage 6 7 8 9 10 SW 30 mm 17 Nm 31461000 32660000 SW 22 mm 2 min SW 22 mm 2 Nm...
Page 15: ...14 Montage 31462000 32664000 17 Nm 2 SW 2 5 mm 1 3 4 5 SW 22 mm 2 min SW 22 mm 2 Nm...
Page 16: ...15 Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3...
Page 18: ...17 Wartung 1 3 1 2 1 2 2...
Page 20: ...19 Metris Puro 31462000 Metris Puro 32664000 Metris Puro 31462000 Metris Puro 32664000 1 2 1B...
Page 23: ...22...
Page 24: ...23...