2
SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Dimensions
(see page 7)
Operation
(see page 6)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Do not use silicone containing acetic acid!
Flowdiagram
(see page 7)
Spareparts
(see page 8)
Cleaning
(see page 6)
Symboldescription
Assemblyseepage4
Adjustment
(see page 5)
To adjust the hot water limiter. Using a
hot water limiter in combination with
a continuous flow water heater is not