6
If the water is hotter than the maximum temperature
permitted by local code (110° - 112°F in many areas),
reset the rotational limit stop (see below).
Install the handle adapter and screw.
Install the handle. Tighten the handle screw with a 3mm
Allen wrench.
Set the rotational limit stop (high temper-
ature limit stop)
The rotational limit stop may need to be adjusted
seasonally, or if changes are made to the water heater.
Remove the handle. Pull the disc away from the
cartridge enough so that you can grasp the rotational
limit stop.
Pull out on the rotational limit stop and turn it clockwise
to make the water cooler, counter-clockwise to make
it warmer. The temperature change per tooth can be
4°F - 16°F, depending on the water conditions. Test.
Repeat if necessary.
Push the disc back into place, until fully
seated. Failure to do so could result in
scald injury.
rotational limit stop
hotter
stem
first position
- least hot
water
disc