Hans Grohe IP C 04210000 Installation Instructions / Warranty Download Page 3

3

Installation considerations

•  For best results, Hansgrohe recommends that 

this unit be installed by a licensed, profes-
sional plumber.

•  Please read over these instructions thoroughly 

before beginning installation.  Make sure that 
you have all tools and supplies needed to 
complete the installation.

•  Pressure balance valve rough 04120000 (not 

included) must be installed, and the finished 
wall surface must be installed and made wa-
tertight before installation of this trim kit.

•  The tub spout (included with 04210000 / 

04199000 / 04203000 only) requires a ½" 
NPT male nipple, extending 4" - 4 ¼" outside 
the surface of the finished wall.

•  The shower arm requires a ½" NPT female 

fitting.

•  The max. flow rate of the valve is 4.5 GPM.

IP C showerhead
1.6 GPM max
Full spray, massage, intense 
massage

IP E,S showerhead
1.6 GPM max
Full spray, massage, intense 
massage

•  The max. flow rate of the showerhead is 1.6 

GPM.

•  The shower valve incorporates a high tem-

perature limit stop which must be set to comply 
with local plumbing codes.

•  This product is for use with shower heads rated 

at 1.5 GPM (5.6 l/min) or higher.

•  To prevent scald injury, the maximum output 

temperature of the shower mixing valve (not 
included) must be no higher than 120°F. In 
Massachusetts, the maximum output tempera-
ture can be no higher than 112°  F.

•  Know and follow all applicable local plumb-

ing codes when setting the temperature on the 
water heater.

½"

3"

5¼"

26°

26°

3¼"

G ½

3"

4"

26°

26°

Summary of Contents for IP C 04210000

Page 1: ...IP C 04210000 04211000 04212000 IP E 04199000 04200000 04201000 IP S 04203000 04204000 04205000 Installation Instructions Warranty ...

Page 2: ...sets only tub spout included with tub shower sets only Valve trim only IP C 04212000 IP E 04201000 IP S 04205000 Shower set includes valve trim shower arm showerhead IP C 04211000 IP E 04200000 IP S 04204000 Tub shower set includes valve trim shower arm showerhead tub spout IP C 04210000 IP E 04199000 IP S 04203000 3 7 3 7 2 5 2 NPT 2 5 5 3 7 ...

Page 3: ...finished wall The shower arm requires a NPT female fitting The max flow rate of the valve is 4 5 GPM IP C showerhead 1 6 GPM max Full spray massage intense massage IP E S showerhead 1 6 GPM max Full spray massage intense massage The max flow rate of the showerhead is 1 6 GPM The shower valve incorporates a high tem perature limit stop which must be set to comply with local plumbing codes This prod...

Page 4: ...n all other installations the plaster shield may be removed if desired Normal installation Insert the cartridge in the valve with the hot side marking on the left Reversed installation cold on left hot on right Insert the cartridge so that the hot side markings are on the right All installations Make sure that the cartridge en gages the holes inside the valve The keys on the sides of the cartridge...

Page 5: ...e screws Test the valve Temporarily install the handle Turn the handle clockwise until it stops Turn the water on at the main Turn the handle counter clockwise The cold water should come on first and become warmer the farther the handle is turned Turn the handle counter clockwise until it stops Measure the temperature of the output water with a thermometer Caution If the hot water comes on first r...

Page 6: ... seasonally or if changes are made to the water heater Remove the handle Pull the disc away from the cartridge enough so that you can grasp the rotational limit stop Pull out on the rotational limit stop and turn it clockwise to make the water cooler counter clockwise to make it warmer The temperature change per tooth can be 4 F 16 F depending on the water conditions Test Repeat if necessary Push ...

Page 7: ...Turn the water off at the main Remove the handle and sleeve Remove the bonnet nut Caution Do not attempt to pry the cartridge out with a screwdriver Position the handle on the stem Turn counter clockwise approximately turn after the stop is contacted Lift the cartridge from the valve body ...

Page 8: ...mage Slide the flange against the wall Showerhead installation Because of the self sealing filter gasket Teflon tape is not necessary Screw the showerhead onto the arm Do not overtighten or damage to the showerhead or arm can result Tub spout installation Seal the wall around the nipple with waterproof sealant Failure to seal the wall can lead to possible water damage Wrap the threads on the nippl...

Page 9: ...hange the spray modes IP C showerhead only turn the function ring to the desired spray mode IP E S showerhead only push the function lever to the desired spray mode Cleaning If scale deposits appear in the spray channels rub across the spray channels with a finger or a sponge to dislodge them function ring function lever ...

Page 10: ...flush the showerhead for at least one minute To remove heavier scale deposits pour about 3 4 of a commercial scale remover such as Lime Away or CLR into a shallow dish Be sure to follow the label instructions Soak the spray face for the amount of time specified in the label instructions ...

Page 11: ... and installed in either the United States or in Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original purchaser only This warranty is non transferable WHAT IS COVERED BY THE WARRANTY The warranty covers only your Hansgrohe manufactured product Hansgrohe warrants this product against defects in material or workmanship as follows Hansgrohe will replace at no charge for parts o...

Page 12: ...ON TO CREATE FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY Some States do not allow the exclusion or limitation of incidental ...

Reviews: