2 (24)
English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
Do not allow the streams of the shower touch
sensitive body parts (such as your eyes). An
adequate distance must be kept between the shower
and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the
fact that a change of installation height will also
change the minimum height, and that the altered
mounting dimensions must be taken into considera-
tion.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply
the product and has no weak points.
• The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt
leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and
guarantee claims.
• The product is not designed to be used with steam
baths!
• If required, the bottom part of the pipe between the
fixture and the shower head can be shortened with a
fine-toothed saw.
• If the continuous water heater causes any problems,
or you have different water pressures you must install
a water limiter to the cold supply, (ordered separate-
ly,article number 97510000).
Assembly
(see page 6)
Pressure and permeability test
The connections of the thermostatic mixer should be
tested regular after installation.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,15 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
160 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 11)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
Adjustment
(see page 10)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
Maintenance
(see page 16)
• The check valves must be checked regularly
according to EN 806-5 in accordance with national
or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Dimensions
(see page 12)
Summary of Contents for Crometta S 240 1jet Showerpipe 27332000
Page 7: ...7 24 2 8 9 10 11 12 6 3 2 7 Armaturenfett Grease 1 SW 4 mm Armaturenfett Grease 1...
Page 9: ...9 24 1 2 SW 17 mm 94246000 15 16 17 SW 3 mm 1 2 3...
Page 10: ...10 24 1 3 4 2 5 6 SW 3 mm SW 3 mm...
Page 11: ...11 24 1 4 6 5 1 2 SW 3 mm for example 42 C till exempel 42 C 2 3 1 2 SW 3 mm...
Page 14: ...14 24 40 C open ppna cold kallt hot varmt close st nga 1 1 2 2...
Page 15: ...15 24 1 2 3 1 2 Crometta Vario 1 Rain 2 IntenseRain...
Page 16: ...16 24 1 2 3 4 3 mm 6 mm 23 mm 1 2 3 4 5...
Page 17: ...17 24 23 mm 3 2 1 4 3 mm 6 mm 7 8 9 6...
Page 19: ...19 24 3 4 5 SW 17 mm SW 17 mm 1 2 1 min 6...
Page 20: ...20 24 1 min 1 3 4 5 2...
Page 22: ...22 24...
Page 23: ...23 24...