(see page 36)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 38)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Dimensions
(see page 39)
Flow diagram
(see page 39)
Spare parts
(see page 42)
Maintenance
(see page 41)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Cleaning
(see page 40)
Operation
(see page 35)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• After periods of prolonged non-use, but at least every
third day, the fittings must be opened with the handle
in hot and cold position to prevent stagnation in the
connecting lines. Let the water run until the water
temperature is constant.
Test certificate
(see page 44)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Cento XL 2jet 14803000
Page 14: ...14 36 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 70 C 4 38 39 39 42 41 EN 806 5 40 35 Hansgrohe 44...
Page 28: ...28 36 1 0 1 0 5 1 6 1 10 147 PSI 60 C 70 C 4 38 39 39 42 41 EN 806 5 40 35 Hansgrohe 44...
Page 29: ...29 36 1 0 5 0 1 1 6 PSI 147 10 1 60 C 4 70 C 38 39 39 42 41 5 EN 806 40 35 Hansgrohe 44...
Page 36: ...36 110 110 150 max 35 mm 3 Nm SW 10 mm SW 19 mm 4 Nm max 60 mm 150 1a 1b 2 3 4 5...
Page 41: ...41 1 1 2 2...
Page 43: ...43...