Technical Data
Operating pressure:
max. 145 psi
Recommended operating pressure: 14.5 - 72 psi
Hot water temperature:
max. 176° F*
Recommended hot water temperature: 120°F - 140°F*
Center distance:
6 3/4“ ± 1 3/4“
Connections ½" female:
cold right
hot left
Tub filler flow rate @ 45 psi
approx. 5.8 gpm
Flow rate for handshower
2.5 gpm
Backflow prevention provided by check valve.
This unit is not anti-scald. If required by local plum-
bing code, install with remote pressure balance valve
13418181.
*Know and follow all applicable local plumbing codes when setting the
temperature on the water heater.
Montreux
Wall-Mount Tub Filler 16540XX1
Wall-Mount Shower Mixer 16560XX1
16540XX1