15
English
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Regulator filter dirty
- Joint-filtre de douchette encrassé
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filters
- Clean filter seal between shower
and hose
Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
- Backflow preventers dirty or leaking - Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Hot water temperature too low
- Adjust thermostat
- Increase hot water temperature to
42 °C to 65 °C
Temperature regulation not possible
- Temperature regulator dirty or
calcified
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180° rotation
- Clean temperature regulator,
exchange if necessary
- Install function block turned through
180°
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Valve stiff
- Shut-off unit damaged
- Exchange shut-off unit
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
120 chrome plated/porcelain colour
800 steel
810 satinox
820 brushed nickel
830 polished nickel