12
English
Set the high temperature limit
stop**
Turn the water on to one of the functions.
Turn the cartridge stem until the output water
is the desired high temperature, usually 110°
- 112° F**.
Replace the stop ring so that the tooth is against
the cartridge stop. Replace the clip.
It should not be possible to turn the stem further
counter-clockwise.
**Follow all applicable local plumbing codes when setting the
high temperature limit stop.
Remove the clip and stop ring from the cartridge
stem.