13
Step 5- Stick the conversion label on the rating plate as shown in Figure 15.
Metal Rating Plate
1.
2.
3.
4.
5.
6.
7.
Figure 15 Conversion Label
LIGHTING INSTRUCTIONS
Warning: If these instructions are not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
1. Make sure the control knob is in the "OFF" position. See Figure 16 Open the
tank
valve all the way.
IGNITER BUTTON CONTROLKNOB
2. Push in the igniter button. You will hear a slight clicking sound. With the
igniter button pushed in, push and turn the control knob to the “ON” position.
the fire should light within a few seconds. Once the flame is lit, release the
igniter button and continue to hold the
Serial Number _________________
Model Number: 98900
CAUTION:
The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors.
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)
Figure 16