background image

IMPORTANT SAFETY INFORMATION 

The installation must conform with local codes or, in the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54; International Fuel Gas Code. ; Natural Gas and Propane 
Installation Code, CSA B149.1; or Propane Storage and Handling Code, B149.2, as applicable. 

The appliance and its appliance main gas valve must be disconnected from the gas supply piping 
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). 

The appliance must be isolated from the gas supply piping system by closing its equipment shutoff 
valve during any pressure testing of the gas supply system at test pressure equal to or less than 
1/2 psi (3.5kPa). 

The appliance area must be kept clear and free from combustible materials, gasoline and other 
flammable vapors and liquids.  

Do not use this appliance if any part has been under water. Immediately call a qualified service 
technician to inspect the appliance and to replace any part of the control system and any gas 
control which has been under water. 

Children and adults should be alerted to the hazards of high surface temperatures and kept 
at a safe distance to avoid burns or clothing ignition. 

Young children should be carefully supervised when they are anywhere near the appliance. 

Clothing or other flammable material should not be hung from the appliance, or placed on 
or near the appliance. 

Any screen or guard removed for servicing an appliance must be replaced prior to 
operating the appliance. 

Installation and repair should be done by a qualified service person. The appliance should 
be inspected before use and at least annually by a professional service person. More 
frequent cleaning may be required as necessary. It is imperative that the control 
compartments, burners and circulating air passageways of the appliance be kept clean. 

Do NOT burn solid fuels in this gas fireplace. 

Do NOT ignite the burner before pouring all of the burner media (lava rock or fire glass) into the 
burner pan. The media must be evenly distributed over the burner. 

CAUTION

: The propane gas pressure regulator provided with this appliance must be used. This 

regulator is set for an outlet pressure of 11 inches water column. 

This outdoor gas appliance is not intended to be installed in or on recreational vehicles and/or 
boats. 

Before each use of this gas appliance, open the LP (Liquid Propane) Tank Drawer and inspect the 
LP Hose. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced 
prior to the gas appliance being put into operation. Use only the replacement hose assembly 
specified in this manual. Inspect the burner before each use of the appliance. The burner must be 
replaced prior to the appliance being put into operation if it is evident that the burner is damaged. 
Use only the burner listed in these instructions.  

Keep the fuel supply hose away from any heated surfaces. 

 

Summary of Contents for BGC08006

Page 1: ...mer Service Hotline at 1 800 416 3511 Between 9 00 AM and 5 00 PM Eastern Time Monday through Friday Or visit our website at www hanover products com To expedite any future warranty claims please reta...

Page 2: ...shown in Attach back of love seat arm by inserting two mm bolts with washers through holes in the back portion of love seat frame and into the holes in the rear portion of the love seat arm as shown...

Page 3: ...X 1 5 MM WASHER LEFT ARM RIGHT ARM BOLT COVER HEX BOLT DRIVER FOOT CAP 1 FACTORY ASSEMBLY HW0005 HW0022 HW0006 FC0030 1 12 HW0275 12 4 5 16 X 25 MM BOLT HW0186 1 1 1 1 BACK FRAME SEAT FRAME PARTS LIST...

Page 4: ...WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing...

Page 5: ...the appliance or placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a q...

Page 6: ...enclosed space When this appliance is not is use the gas must be turned off at the supply cylinder Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed fro...

Page 7: ...385 1 H IGNITION MODULE FP0006 1 I ORIFICE BRACKET FP0311 1 J PROPANE ORIFICE FP1283 1 K NATURAL GAS ORIFICE FP1284 1 L LP TANK RETAINING KNOB FP0585 2 M AAA BATTERY 1 5V HW0705 1 N ADJUSTABLE FOOT CA...

Page 8: ...use bolts and washers as shown in Figure 3 Guide the bolts through the holes in the base brackets into the pre drilled holes in the table top Do not tighten completely Repeat on other three sides Not...

Page 9: ...wn Open the control door and check that the valve is turned all the way clockwise to the OFF position Open the tank valve Apply a solution of soapy water to the tank regulator connection and to the va...

Page 10: ...eak If a leak is found close the main valve and tighten all connections NEVER USE A FLAME TO CHECK FOR LEAKS 3 Stick the conversion label on the rating plate as shown in Figure 9 Metal Rating Plate Fi...

Page 11: ...the flame push the control knob in slightly and turn to the Medium medium flame or Low small flame 4 To shut down the fire pit turn the control knob to the OFF position and turn off the tank valve Fi...

Page 12: ...dule Check that the electrode is not cracked or broken Burner won t light Lack of oxygen Remove excess lava rocks or fire ices from around the ignition well Thermocouple not in flame Check that the ti...