![Hanover BGC08006 Assembly Instructions Manual Download Page 10](http://html2.mh-extra.com/html/hanover/bgc08006/bgc08006_assembly-instructions-manual_3679166010.webp)
NATURAL GAS CONVERSION
Natural gas conversion must be performed only by your natural gas provider or
service company.
1.Disconnect the regulator hose from the gas valve. See Figure 8.
Figure 8
2.Disconnect the gas tube from the orifice elbow. Remove the two M4 nuts and remove
the orifice holder. Replace the propane orifice with the natural gas orifice from the kit and
reinstall the orifice holder. Apply a solution of soapy water to all connections to check for
leaks. If soap bubbles continue to form, the connection has a leak. If a leak is found, close
the main valve and tighten all connections.
NEVER USE A FLAME TO CHECK FOR
LEAKS.
3.Stick the conversion label on the rating plate as shown in Figure 9.
Metal Rating Plate
Figure 9
Conversion Label
Serial Number _________________
Model Number: 98910
CAUTION:
The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors.
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)