ELECTRODES
HI 1048B

Glass body, double junction, refillable pH electrode with
BNC connector and 1 m (3.3') cable, for wine, must and
grape juice

FC 100B

PVDF

 

body, double junction, refillable, pH electrode with

BNC connector and 1 m (3.3') cable, for food industry

FC 200B

PVDF

 

body, open junction, conic tip, Viscolene, non-refillable

pH electrode with BNC connector and 1 m (3.3') cable, for
meat & cheese

FC 210B

Glass body, double junction, conic tip, Viscolene, non-
refillable pH electrode with BNC connector and 1 m (3.3')
cable, for milk and yogurt

HI 3131B

Glass body, refillable, platinum ORP electrode

HI 3230B

Plastic body, gel-filled, platinum ORP electrode

HI 4430B

Plastic body, gel-filled, gold ORP electrode

OTHER ACCESSORIES
HI 710005

115 Vac/12 Vdc power adapter, US plug

HI 710006

230 Vac/12 Vdc power adapter, European plug

HI 76405

Electrode holder

HI 8427

pH and ORP electrode simulator with 1 m (3.3') coaxial
cable ending in female BNC connectors

HI 931001

pH and ORP electrode simulator with LCD and 1 m (3.3')
coaxial cable ending in female BNC connectors

HI 98501

Pocket-size thermometer (range -50.0 to 150.0°C)

Recommendations for Users

Before using this product, make sure that it is entirely suitable for the environment in which it is used.

Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipment, requiring the
operator to take all necessary steps to correct interferences.

The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times.
During calibration of instruments, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic
discharge.

To maintain the EMC performance of this equipment, the recommended cables noted in the user's manual must be used.
Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance.

To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 Vac or 60 Vdc.

To avoid damage or burns, do not perform any measurement in microwave ovens.

WARRANTY

All Hanna Instruments

 meters are guaranteed for two years 

against defects

in workmanship and materials when used for their intended purpose and
maintained according to instructions.

Electrodes and probes are guaranteed for a period of six months.

This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance
are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure. If the repair is not covered by the
warranty, you will be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods Authorization
number from the Customer Service department and then send it with shipping
costs prepaid. When shipping any instrument, make sure it is properly
packaged for complete protection.

All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner.

Hanna Instruments reserves the right to modify the design, construction and

appearance of its products without advance notice.

Summary of Contents for pH 209V

Page 1: ...Instruction Manual w w w h a n n a i n s t c o m pH 209V Complete Laboratory Kit for pH ORP Measurements in Wine Must and Grape Juice ...

Page 2: ...des pH 209 bench pH meter HI 1048B pH electrode HI 98501 electronic thermometer pH 3 and pH 7 buffer solutions 20 mL sachet each HI 700635 and HI 700636 specific cleaning solutions 20 mL each HI 7082 electrode refilling solution 30 mL bottle and syringe HI 76404 electrode holder 12 Vdc adapter and instruction manual Note Save all packing material until you are sure that the instrument functions co...

Page 3: ...le with BNC and 1 m 3 3 cable Input Impedance 1012 ohm Power Supply 12 Vdc adapter included Environment 0 to 50 C 32 to 122 F RH max 95 non condensing Dimensions 240 x 182 x 74 mm 9 4x7 2x2 9 Weight 1 0 kg 2 2 lb meter only SPECIFICATIONS 1 Liquid Crystal Display LCD 2 pH slope adjustment knob 3 pH offset adjustment knob 4 pH range selection key 5 mV range selection key 6 C range selection key 7 T...

Page 4: ...Vdc adapter into the power supply socket 9 on page 4 Note Make sure the main line is protected by a fuse Electrode connection For pH or ORP electrodes with internal reference connect the electrode to the BNC socket on the rear panel 10 on page 4 For electrodes with separate reference plug the BNC connector of the electrode to the BNC socket 10 on page 4 and the reference electrode to the proper so...

Page 5: ...rence Switch the instrument on by pressing the ON OFF button Rinse and immerse the pH electrode in pH 7 01 buffer and shake briefly Wait a couple of minutes for the reading to stabilize Note the temperature of the buffer solution using the supplied HI 98501 thermometer e g 20 C Press the C key to select temperature setting then adjust the Temperature knob until the LCD shows the noted temperature ...

Page 6: ...e the electrode Refilling the electrode ALWAYS VERIFY THE ELECTROLYTE LEVEL If the electrolyte level is more than 2 cm below the refilling hole unscrew and remove the refill ing hole cap Add the 3 5M KCl electrolyte solution HI 7082 by using the supplied syringe Tighten back the cap Wait at least 1 hour before using the electrode pH VALUES AT VARIOUS TEMPERATURES pH readings are strongly affected ...

Page 7: ...trodes ORP PRETREATMENT SOLUTIONS HI 7091L Reducing pretreatment solution 500 mL bottle HI 7092L Oxidizing pretreatment solution 500 mL bottle Cleaning procedure After use clean the electrode by immersing it in the proper cleaning solution HI 700635 or HI 700636 for 5 minutes If case of slow and unreliable readings it is recommended to perform the following procedure for cleaning the junction 1 Sh...

Page 8: ...g calibration of instruments ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharge To maintain the EMC performance of this equipment the recommended cables noted in the user s manual must be used Any variation introduced by the user to the supplied equipment may degrade the instrument s EMC performance To avoid electrical shock do not use this instrum...

Page 9: ...2942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739 3014 Fax 886 2 2739 2983 Thailand Tel 66 2619 0708 Fax 66 2619 0061 UnitedKingdom Tel 01525 850 855 Fax 01525 853 668 USA Tel 401 765 7500 Fax 401 765 7575 For e ma...

Reviews: