background image

Reagent Sets

HI93722-01

Reagents for 100 tests

HI93722-03

Reagents for 300 tests

Other Accessories

HI96722-11

CAL Check™

 Standard Cuvettes (1 set)

HI740029P

9V battery (10 pcs.) 

HI731318

Cloth for wiping cuvettes (4 pcs.)

HI731331

Glass cuvetes (4 pcs.)

HI731335

Caps for cuvettes (4 pcs.)

HI93703-50

Cuvette cleaning solution (230 mL)

ACCESSORIES

HI96722

 is warranted for two years against defects in workmanship and 

materials when used for its intended purpose and maintained according 
to the instructions.
This warranty is limited to repair or replacement free of charge. 
Damages due to accident, misuse, tampering or lack of prescribed main-
tenance are not covered.
If service is required, contact your local Hanna Instruments Office. If under 
warranty, report the model number, date of purchase, serial number and 
the nature of the failure. If the repair is not covered by the warranty, you 
will be notified of the charges incurred. 
If the instrument is to be returned to Hanna Instruments, first obtain a 
Returned Goods Authorization Number from the Customer Service Depart-
ment and then send it with shipment costs prepaid. When shipping any 
instrument, make sure it is properly packaged for complete protection. 
To validate your warranty, fill out and return the enclosed warranty card 
within 14 days from the date of purchase.

WARRANTY

IST96722  01/18

Hanna Instruments reserves the right to modify the design, construction, or  

appearance of its products without advance notice.

All rights are reserved. Reproduction in whole or in part is prohibited with-

out the written consent of the copyright owner, Hanna Instruments Inc., 

Woonsocket, Rhode Island, 02895, USA

Thank You

Thank you for choosing a Hanna Instruments product. Please read 
this instruction manual carefully before using the instrument. 
For more information about Hanna Instruments and our products, 
visit www.hannainst.com.
For technical support, contact your local Hanna Instruments Office 
or e-mail us at [email protected]
Find your local Hanna Instruments Office at www.hannainst.com

Please examine this product carefully. Make sure that the instrument is not 
damaged. If any damage occured during shipment, please contact your local 
Hanna Instruments Office.
Each 

HI96722

 Ion Selective Meter is supplied complete with: 

• Sample Cuvettes and Caps (2 pcs.)
• 9V Battery
• Instruction Manual
• Quality Certificate

Note: Save all packing material until you are sure that the instrument 

works correctly. Any defective item must be returned in its original 

packing.

PRELIMINARY EXAMINATION

 

For more details about spare parts and accessories see 

“Accessories”.

SPECIFICATIONS

Range

0 to 80 mg/L

Resolution

1 mg/L

Accuracy 
@25 

°

C (77 

°

F)

1 mg/L ±15% of reading

Light source

Tungsten lamp

Light Detector

Silicon Photocell with narrow band interference 
filter @525 nm

Method

Adaptation of the turbidimetric method. The 
reaction between cyanuric acid and the reagent 
causes a white suspension in the sample.

Environment

0 to 50 

°

C (32 to 122 

°

F); 

max 95% RH non-condensing

Battery Type

9V (1 pc.)

Auto-Shut off

After 10’ of non-use in measurement mode;
after 1 hour of non-use in calibration mode;
with last reading reminder

Dimensions

192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)

Weight

320 g (11.3 oz.)

FUNCTIONAL DESCRIPTION

1.  

GLP/  

key: press to enter GLP mode. In calibration mode press to 

edit the date and time.

2. 

CAL CHECK

 key: press to perform the validation of the meter, or press 

and hold for three seconds to enter calibration mode. 

3. 

ZERO/CFM

 key: press to zero the meter prior to measurement, to 

confirm edited values or to confirm factory calibration restore.

4. 

READ /TIMER 

key: In measurement mode, press to make a 

measurement, or press and hold for three seconds to start a 
preprogrammed coutdown prior to measurement. In GLP mode press 
to view the next screen.

5. 

ON/OFF

 key: to turn the meter on and off.

6.  Liquid Cristal Display (LCD)
7.  Cuvette alignment indicator
8.  Cuvette holder

  1. The measuring scheme (lamp, cuvette, detector), appears during 

different phases of zero or reading measurement

  2. Error messages and warnings
  3. The battery icon indicates the charge state of the battery
  4. The hourglass appears when an internal check is in progress
  5. Status messages
  6. The chronometer appears when the reaction timer is running
  7. The month, day and date icons appear when a date is displayed
  8. Four digit main display
  9. Measuring units
10. Four digit secondary display

DISPLAY ELEMENTS DESCRIPTION

O

Z

ero

 R

eading:

ERRORS AND WARNINGS

Light High:

 There is too much light to perform 

a measurement. Please check the preparation of 
the zero cuvette.

Light Low:

 There is not enough light to perform 

a measurement. Please check the preparation of 
the zero cuvette.

On Sample Reading:

No Light:

 The instrument cannot adjust the light 

level. Please check that the sample does not contain 
any debris.

Inverted cuvettes:

 The sample and the zero cuvette 

are inverted.

Zero:

 A zero reading was not taken. Follow the 

instructions of the measurement procedure for 
zeroing the meter. 

Under range:

 A blinking 

“0.0”

 indicates that the 

sample absorbs less light than the zero reference. 
Check the procedure and make sure you use the 
same cuvette for reference (zero) and measurement.

Over Range:

 A flashing value of the maximum 

concentration indicates an over range condition. 
The concentration of the sample is beyond the 
programmed range: dilute the sample and re-run 
the test.

During Calibration Procedure:

Standard Low:

 The standard reading is less than 

expected.

Standard High:

 The standard reading is higher 

than expected.

Other Errors And Warnings:

Cap error:

 Appears when external light enters 

in the analysis cell. Assure that the cuvette cap 
is present.

Cooling lamp:

 The instrument waits for the lamp 

to cool down.

Battery low:

 The battery must be replaced soon.

Dead battery:

 This indicates that the battery is 

dead and must be replaced. Once this indication 
is displayed, normal operation of the instrument 
will be interrupted. Change the battery and restart 
the meter.

1•

 

Turn the meter on by pressing 

ON/OFF

.

2•

  When the beeper sounds briefly and the 

LCD displays dashes, the meter is ready. 
The blinking 

“ZERO”

 indicates that the 

instrument needs to be zeroed first.

3•

  Fill a cuvette with 10 mL of unreacted 

sample, up to the mark, and replace the 
cap.

4•

  Place the cuvette into the holder and ensure 

that the notch on the cap is positioned 
securely into the groove.

5•

 Press 

ZERO/CFM

 and the lamp, cuvette and 

detector icons will appear on the display, 
depending on the measurement phase.

6•

  After a few seconds the display will show      

“-0.0-”

. The meter is now zeroed and ready 

for measurement.

7•

  Remove the cuvette.

8•

  Fill a beaker up to the 25 mL mark with the 

sample, add the content of one packet of  

HI93722-0

 

reagent and stir gently to mix.

9•

  Fill a second cuvette with 10 mL of the 

reacted sample, up to the mark, and replace 
the cap.

10•

 Place the second cuvette  into the holder 

and ensure that the notch on the cap is 
positioned securely into the groove.

11•

Press and hold 

READ /TIMER

 for three 

seconds. The display will show the count-
down prior to measurement. The beeper is 
playing a beep at the end of countdown 
period. 

      Alternatively, wait for 45 seconds and just 

press 

READ /TIMER. 

In both cases, the lamp, cuvette and 
detector icons will appear on the display, 
depending on the  measurement phase.

12• 

The instrument directly displays concentra-
tion in mg/L of cyanuric acid on the Liquid 
Crystal Display.

4

5-6

8-9

10

11

10mL

10ml

10mL

10ml

HI9

37

22-

0

MEASUREMENT PROCEDURE

Measurement

 

2

3

3''

 or

12

Summary of Contents for HI96722

Page 1: ...INSTRUCTION MANUAL HI96722 Cyanuric Acid ISM ...

Page 2: ...n Manual Quality Certificate Note Save all packing material until you are sure that the instrument works correctly Any defective item must be returned in its original packing PRELIMINARY EXAMINATION For more details about spare parts and accessories see Accessories SPECIFICATIONS Range 0 to 80 mg L Resolution 1 mg L Accuracy 25 C 77 F 1 mg L 15 of reading Light source Tungsten lamp Light Detector ...

Page 3: ...own prior to measurement In GLP mode press to view the next screen 5 ON OFF key to turn the meter on and off 6 Liquid Cristal Display LCD 7 Cuvette alignment indicator 8 Cuvette holder 1 The measuring scheme lamp cuvette detector appears during different phases of zero or reading measurement 2 Error messages and warnings 3 The battery icon indicates the charge state of the battery 4 The hourglass ...

Page 4: ...25 mL mark with the sample add the content of one packet of HI93722 0 reagent and stir gently to mix 9 Fill a second cuvette with 10 mL of the reacted sample up to the mark and replace the cap 10 Place the second cuvette into the holder and ensure that the notch on the cap is positioned securely into the groove 11 Press and hold READ TIMER for three seconds The display will show the count down pri...

Page 5: ...or zeroing the meter Under range A blinking 0 0 indicates that the sample absorbs less light than the zero reference Check the procedure and make sure you use the same cuvette for reference zero and measurement Over Range A flashing value of the maximum concentration indicates an over range condition The concentration of the sample is beyond the programmed range dilute the sample and re run the te...

Page 6: ...t covered by the warranty you will be notified of the charges incurred If the instrument is to be returned to Hanna Instruments first obtain a Returned Goods Authorization Number from the Customer Service Depart ment and then send it with shipment costs prepaid When shipping any instrument make sure it is properly packaged for complete protection To validate your warranty fill out and return the e...

Page 7: ... icons together with CAL CHECK will appear on the display depending on the measurement phase 9 At the end of the measurement the display will show the validation standard value The reading should be within specifica tions as reported on the CAL Check Standard Certificate If the value is found out of specifications please check that the cuvettes are free of fingerprints oil or dirt and repeat valid...

Page 8: ...or reading calibration standard 7 Remove the cuvette 8 Place the CAL Check Standard HI96722 11 Cuvette B into the holder and ensure that the notch on the cap is positioned securely into the groove 9 Press READ TIMER and the lamp cuvette and detector icons will appear on the display depending on the measure ment phase 10 The instrument will show for three seconds the CAL Check standard value Note I...

Page 9: ...bration is saved 19 The instrument will return automatically to measurement mode by displaying dashes on the LCD LAST CALIBRATION DATE 1 Press GLP to enter GLP mode The calibration month and day will appear on the main display and the year on the secondary display 2 If no calibration was performed the factory calibration message F CAL will appear on the main display and the instrument returns to m...

Page 10: ... and accurate measurements can t be taken any more the instrument shows dEAd bAtt and turns off To restart the instrument the battery must be replaced with a fresh one To replace the instrument s battery follow the steps Turn the instrument off by pressing ON OFF Turn the instrument upside down and remove the battery cover by turning it counterclockwise Extract the battery from its location and re...

Reviews: