HI 93522

 allows the user to select the auto-off time period through

the keyboard; press (ALT+) AOFF to enter the mode, then set the
desired auto shut-off interval (8 min, 60 min, or disabled) with the
ALT key; release all buttons, wait a few seconds and the meter will
return to normal measurement mode.

BACKLIGHT FEATURE (HI 93510N and HI 93522)

HI 93510N

 and 

HI 93522

 models are provided with a Backlight

feature, which can be easily activated through the keyboard by
pressing the BL key or (ALT+)BL keys.

Note

: The backlight automatically shuts off after approximately 1

minute with no buttons pressed.

BATTERY COMPARTMENT

2-CHANNEL MODELS (HI 93512 and HI 93522)

HI 93512

 and 

HI 93522

 models can monitor two samples through

two independent temperature channels (probes).
The display will show the actual, Hi and Lo (or T1 and T2) values of
the selected channel (T1, T2 or T1-T2). The corresponding tag will
light up to inform the user.
To select the desired channel, use the T1/T2 key.

The 2-channel models are also provided with the DISP function, which
allows the user to select the information to be displayed.
• While in T1 or T2, pressing DISP will switch the display between

standard and relative measurement modes.
In the standard mode, the main body of the LCD shows the
current temperature while the lower portion displays the Hi/Lo
limits for that channel.
When the meter enters relative mode, the current temperature for
that channel is set as the reference temperature. Pressing CLR will
also set the reference to the current temperature.

In relative mode, the main body of the LCD shows the difference
from the reference temperature. The lower portion displays the
current temperature for the selected channel.

• While in T1-T2, pressing DISP will switch between 3 displays:

Note

: Pressing T1/T2 to change the channel will not alter the

information chosen to be displayed for each channel (DISP).

Note

: Relative mode can not be entered if dashes are shown in the

main portion of the LCD.

HI 93522

HI 93510N

Summary of Contents for HI 93510N

Page 1: ...Instruction Manual HI 93510 HI 93510N HI 93512 HI 93522 PortableMicroprocessor ThermistorThermometers w w w h a n n a i n s t c o m...

Page 2: ...and probe can be calibrated in an ice bath at 0 C or dimly lit areas the backlight feature can be easily activated through the keyboard HI 93512 is a two channel thermometer ideal for monitoring two...

Page 3: ...obes series Available HI 762 accuracy test plugs Display of temperature in degrees Celsius or Fahrenheit Range 50 to 150 C or 58 to 302 F HOLD function HI and LO Max and Min temperature values always...

Page 4: ...with HI 762BL probe Battery 3x1 5V AA IEC LR6 batteries approx 2000 hours of continuous use BL off Auto off user selectable 8 min 60 min disabled HI 93522 only Environment 10 to 50 C 14 to 122 F RH 1...

Page 5: ...mpartment see figure on page 10 Unscrew the 4 screws on the back of the meter and select the desired auto off time period by pressing the button and viewing the value on the LCD Reattach the back maki...

Page 6: ...light up to inform the user To select the desired channel use the T1 T2 key The 2 channel models are also provided with the DISP function which allows the user to select the information to be displaye...

Page 7: ...then automatically returns to normal mode Note To exit the Calibration mode at any time press the CAL key Note User calibration cannot be entered in relative or in T1 T2 mode Note User calibration is...

Page 8: ...obe w 10 m 33 cable white handle HI 762PBL General purpose penetration probe w 1 m 3 3 cable blue handle HI 762PBL 10 General purpose penetration probe w 10 m 33 cable blue handle HI 762PG General pur...

Page 9: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Reviews: