15
15
PRINTING / LOGGING
PRINTING / LOGGING
PRINTING / LOGGING
PRINTING / LOGGING
PRINTING / LOGGING
WITH HI 92801 AND HI 92804
WITH HI 92801 AND HI 92804
WITH HI 92801 AND HI 92804
WITH HI 92801 AND HI 92804
WITH HI 92801 AND HI 92804
10-01-96
0001 *10.24
#1 20.0
#2 45.4
#3 -----
#4 -----
.
.
.
.
a
b
c
d
e
To print the measured values shown on the
display, press the PRINT key. This function can
be activated in normal operation mode as well
as during logging and scanning data on dis-
play (see above). When in measurement mode, the printout provides
the following information:
a -Running sample number
b -Date
c -Time
d -Temperature value/s
e -Channel number (
HI 92804
only)
LOGGING MODE
This function is suggested when remote measurements have to be
taken automatically without the necessity of an operator and for a
long period of time. In this mode data will be stored directly into
memory.
Set the appropriate logging interval (see Operational Guide section
on page 8).
Press the ALT and the LOG keys simultaneously to enter the logging
mode. The log number and page number will appear for a few
seconds on the display to indicate the correct operational mode.
The printer will print a complete set of data and the "LOG" symbol
will appear on the bottom left corner of the LCD.
UP
DOWN
TIME
LOG
ALT
TEMP
LOG
Log number
Page number
CH
°C
LOG
==07== 0005M
0001 *14.25
#1 25.0 °C
#2 27.3 °C
.
.
Untitled-27
16
16
CH
°C
LOG
UP
PAPER
ALT
TEMP
10-01-96
==07== 0005M
0014 *14.25
#1 25.0 °C
#2 27.3 °C
.
.
b
c
d
a
e
f
To continue logging without printing, press now the ALT and the
PAPER keys at the same time and the "LOG" symbol on display will
start to blink.
After approximately 5 minutes the display will switch off but the
logging function remains active.
To reactivate the display press the TEMP key.
If you wish to restart printing press the ALT
and PAPER keys simultaneously again.
The printout provides the following information:
a - Date (DD-MM-YY)
b - A running log number
c - Running sample number (in that
particular lot)
d - Printing interval indicator in minutes
e - Time (HH-MM)
f - Temperature value/s
Notes:
•
Once in the logging mode, the inter-
val cannot be changed. Exit the
logging mode first (pressing the ALT
and the LOG keys) before setting the
new interval.
•
If the PRINT key is pressed while in
logging mode, a printout is produced
without affecting the running sample
number.
SAMPLE NUMBER
During logging it is possible to know the run-
ning sample number. Press the LOG key twice
and the display will show the number of
values that have been taken in the current
log.
UP
DOWN
TIME
LOG
ALT
TEMP
LOG