Hanna Instruments HI 8410 Instruction Manual Download Page 19

19

All HANNA instruments

®

 

meters are warranted for two years 

against

defects in workmanship and materials when used for their intended
purpose and maintained according to instructions.

The probes are warranted for a period of one year

.

This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure. If the repair is not covered by
the warranty, you will be notified of the charges incurred.
If the instrument is to be returned to HANNA instruments

®

, first obtain a

Returned Goods Authorization Number from the Customer Service depart-
ment and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for
complete protection.

All rights are reserved. Reproduction in whole or in part is prohibited

without the written consent of the copyright owner.

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the
environment in which they are used.
Operation of these instruments in residential area could cause unacceptable
interferences to radio and TV equipments, requiring the operator to take all
necessary steps to correct interferences.
The trimmers are sensitive to electrostatic discharges. It is recommended to use
anti-static screwdrivers.
Unplug the instrument from the power supply before replacing the fuse. External
cables to be connected to the rear panel should end with cable lugs.
To maintain the EMC performance of this equipment, use the proper cables.
Any variation introduced by the user to the supplied equipment may degrade the
instruments' EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the
measurement surface exceed 24 Vac or 60 Vdc.
To avoid damages or burns, do not perform any measurement in microwave ovens.

WARRANTY

WARRANTY

WARRANTY

WARRANTY

WARRANTY

Summary of Contents for HI 8410

Page 1: ...10 Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen P P P P Process Controller rocess Controller rocess Controller rocess Controller rocess Controller w w w h a n n...

Page 2: ...sitate to e mail us at tech hannainst com tech hannainst com tech hannainst com tech hannainst com tech hannainst com These instruments are in compliance with the directives TABLE OF CONTENTS TABLE OF...

Page 3: ...dforthetemperatureeffectsontheoxygensolu bility and membrane permeability Moreover the salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters The instruments a...

Page 4: ...and set the working dosing point SALINITYg L Todisplayandsetthesalinityfactor activeonly in mg L range TEST100 Diagnosticfunction activeonlyin DOrange C To display the temperature reading When a key...

Page 5: ...e is active ALARM To indicate an alarm condition DOSAGEMODESWITCH To indicate that the continuous ON or OFF mode is selected from dosing switch SWITCHES OFF AUTO ON To select the dosing mode OFF dosin...

Page 6: ...EAR PANEL OF HI 8410 1 DO probe connection terminals 2 SET terminals for connection to a dosing pump 3 ALARM terminals for connection to an external alarm device 4 Power supply terminals 5 Fuse holder...

Page 7: ...tout size for the installation Side view of the panel mounted unit Adjustablelocationbrackets suppliedwiththemeter allowtheindicator to slide into the cutout and will hold the unit securely in place 1...

Page 8: ...e see figure 3 Rinse the supplied membrane HI 76410A with electrolyte while shaking it gently Refill with clean electrolyte Gently tap the membrane over a surface to ensure that no air bubbles remain...

Page 9: ...o 60 min with knob or Disable by wire strap on rear panel Continuous ON 115 or 230 Vac 10 user selectable 60 50 Hz Black anodized aluminum body front and back with ABS transparent splash proof front c...

Page 10: ...ermited In order to avoid malfunction leave unconnected the unused terminal REAR CONNECTIONS FOR HI 8410 Power Connection Terminals 4 screw terminal strip for connection to a 3 wire power cable accord...

Page 11: ...isabletheovertimedosagefeaturemake a short with a jumper wire between the ter minalsoftheproperconnectors seepicture terminals 1 2 Hysteresis knob Put the hysteresis knob in the desired posi tion The...

Page 12: ...librated Ensure the D O probe is immersed in the sample to be tested The D O reading can be displayed in air saturation or in ppm mg L according to the range selection switch The corresponding LED is...

Page 13: ...the set point set point hysteresis overpassed stop dosing set point start dosing SALINITY g L SET mg L range only Oxygenmeasurementscanbecompensatedforsalinityconcentrationand this correction value c...

Page 14: ...n value Enter the mg L mode Press the SALINITY g L button Turn the SALINITY trimmer to display the salinity value corresponding to the desired altitude See below table for reference ALARM Press the AL...

Page 15: ...notwithinthetoleranceofthesetvalue the alarm contact will be open HYSTERESIS SET Turn the hysteresis knob rear panel in the desired position from 0 5 to 2 4 mg L range Thedosagewillbeactiveaccordingto...

Page 16: ...n section for details Switch the meter on select the DO mode and turn the CAL trimmer to display100 If the environmental relative humidity is lower than 30 pour some deionized water approx 3 mm in the...

Page 17: ...rblinking 25 ON in accordance with the dosage relay status inactive active In SET mode it is ON or blinking 75 ON in accordance with the dosage relay status inactive active ALARM LED InMEASUREmodeitis...

Page 18: ...o be replaced by authorized technical personnel only PROBE MAINTENANCE CLEANING PROBE MAINTENANCE CLEANING PROBE MAINTENANCE CLEANING PROBE MAINTENANCE CLEANING PROBE MAINTENANCE CLEANING Foratopperfo...

Page 19: ...rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Recommendations for Users Before using these products make sure that they are enti...