48
program. If “Work” and “Pause” are set the agitator will function intermittently
relative to the time settings. In this panel the agitator number is used as the index.
This panel displays and allows the setting of the following parameters:
Pre
The selectable pre-activation time for the agitator. The pre-agitation is done
only if the program has pre-irrigation and during of it.
Program Number
Reflects the selected program (can be selected only inside panel
C 03
). See
Section 5.2.
Work
The selectable activation time for the indexed agitator. Working time during
irrigation.
Pause
The selectable pause time following work time setting.
5.7.15 FILTERS CTRL – S 46
Link 05 Filter 01
Clean on alarm: Y
Clean time: 01:01:02
FILTERS CTRL S46
Both filter-cleaning programs are set via this panel. In this panel the Filter num-
ber is used as the index. This panel displays and allows the setting of the follow-
ing parameters:
Link
The selectable program (number) after which the filter-cleaning program is
activated.
Filter Number
Panel index. Two filter selectable.
Clean on alarm
The filter-cleaning program can be set to be activated by an alarm condi-
tion alone or in addition to being linked to a specific program. Enter Y (yes)
or N (no).
Clean time
Selectable work duration for the indexed filter cleaning program.
Summary of Contents for HI 8001
Page 12: ...12...
Page 68: ...68 9 ELECTRICAL DIAGRAMS...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71 POWER BOARD EXTENSION BOARD MAIN BOARD...
Page 74: ...74 APPENDIX 3 GRAPHICAL EXPLANATION...
Page 75: ...75...
Page 76: ...76...
Page 85: ...85 APPENDIX 5 INSTALLATION BLOCK DIAGRAM...
Page 86: ...86...
Page 88: ...88 w w w h a n n a i n s t c o m MAN8001 07 03...