1.0 INSTALLATION

1.1 Operating conditions

Maximum operating pressure: 250 psig, 17.6 kgf/cm

2

,

17.2 bar
Maximum compressed air temperature: 180

°

F, 82

°

C

Minimum/maximum ambient temperature: 10/130

°

F,

-12/54

°

C

1.2 Mounting

A.

Changing orientation on units with Monitor
installed

1.

Remove Monitor mounting screw.

2.

Lift Monitor and turn 180

°

.

Note:  Make certain that connector to mounting block is
not disconnected.

3.

Reinstall Monitor to mounting block with mounting
screw.

B.

Retro-fitting bowl/head type housings

Make certain filter is depressurized before disassembly.

1.

Remove existing differential pressure devices or port
plugs if installed.

2.

Install mounting block on filter head using o-rings,
gaskets and transmission bolts supplied with Monitor.

NOTE:  Torque bolts to 30 inch-pounds (3.4 N-m). Do not
over tighten.

IMPORTANT:  Mount block so that raised rectangle is next to
the INLET (high pressure or upstream) side of filter.
Note: Enlarge opening in cap if necessary.  A pattern for a
larger cutout is located on underside of cap.

3.

Connect lead from Monitor to prongs in mounting
block.

IMPORTANT:  Position connector so that legs on connector
are on same side as raised rectangle.

4.

Mount Monitor on mounting block using mounting
screw provided.

NOTE:  Monitor may be rotated 180

°

 so that it faces forward

with filter flowing from left-to-right or right-to-left.

C.

Pressure vessel type housings

Make certain filter is depressurized before disassembly.
1.

If mounting hardware has not been previously
installed, remove inlet/outlet port plugs and  install
fittings, tubing, couplings, and brackets using parts
from Mounting Kit.

2.

Connect mounting block to couplings using o-rings
and transmission bolts supplied with  Monitor.

NOTE:  Torque bolts to 30 inch-pounds (3.4 N-m). Do not
over tighten.

IMPORTANT: Mount block so that raised rectangle is next to
the INLET (high pressure or upstream side) connection.

3.

Connect lead from filter monitor to prongs in
mounting block.

IMPORTANT: Connect so that legs on connector are on same
side as raised rectangle.

4.

Mount Monitor on mounting block using mounting
screw provided.

2.0 OPERATION

2.1 Display Legend

LED DISPLAY

1. Unit of measure selection - pressure  - pounds per

square inch.

2. Unit of measure selection - pressure - kilograms per

square centimeter.

3. Unit of measure selection - pressure - bar.

MONITOR

OPTIONAL 
FILTER 
BRACKET

LEAD

CAP

LEAD

MOUNT WITH LEGS FACING
RAISED RECTANGLE

MOUNT WITH 
RAISED RECTANGLE 
ON INLET SIDE

IN

OUT

O-RINGS

MOUNTING 
BLOCK

TRANSMISSON 
BOLTS

ENLARGE OPENING 
IF NECESSARY

MOUNTING SCREW

LEG

LEG

GASKETS

LEAD

MOUNT WITH LEGS FACING
RAISED RECTANGLE

MOUNT WITH 
RAISED RECTANGLE 
ON INLET SIDE

LEG

MOUNT TO VESSEL 
AS SHOWN
OR REMOTELY TO WALL.

IN

OUT

SHIFT LEFT 
BUTTON

SHIFT RIGHT 
BUTTON

SCROLL
BUTTON

ENTER
BUTTON

OPERATOR 
ALERT LIGHT
(RED LED)

LIQUID
CRYSTAL
DISPLAY

1

2

3

4

5

6

7

9

10

11

12

13

14

15

16

17

8

2

Reviews: