Operation Manual – VPLS
H3C S9500 Series Routing Switches
Chapter 1 VPLS Configuration
1-26
[PE] vlan 100
[PE-vlan100] port Ethernet 4/1/6
[PE-vlan100] quit
[PE] interface Vlan-interface 100
[PE-Vlan-interface100] l2 binding vsi aaa
[PE-Vlan-interface100] quit
After completing the above configurations, you can execute the
display vpls
connection
command on the UPE. There should be two PW connection established,
with one in up state and the other in block state.
[UPE] display vpls connection vsi aaa
2 total connections,
connections: 1 up, 1 block, 0 down
VSI Name: aaa Signaling: ldp
VsiID VsiType PeerAddr InLabel OutLabel LinkID VCState
500 vlan 60.1.1.1 131078 131074 1 up
500 vlan 60.2.2.2 131082 131086 2 block
1.13 Troubleshooting VPLS
Symptom:
The VPLS link PW is not up.
Analysis:
z
The public network LSP tunnel is not established.
z
The extended session is not working normally.
z
A private VLAN virtual interface is not bound with the corresponding VPLS
instance and is not up.
z
The MTU parameters of the VPLS instances in LDP mode on the two peers are
not consistent.
z
If the VLAN interface is not up, the PW is not either.
Solution:
z
Check the routing tables of the PEs to see whether a route is available between
the two PEs. Check whether each device can ping the loopback interface of the
peer and whether the LDP session is normal.
z
Check whether any extended session configuration command is missing at either
side.
z
Check whether the private network interfaces are up or whether the PW to the
UPE is up.
z
Check whether the two peers have the same MTU for VPLS instance, the same
VC ID and the same transmission mode.