background image

For more information

www.haneco.com.au

1300 001 LED

Art11102022

PAGE 2

MOTION SENSOR & REMOTE

HANECO LIGHTING USER GUIDE

HIGHBAY-MS + HIGHBAY-REMOTE

 FOR SKYLUX-G4/SL/SP AND BENZINA-G2

Microwave Motion Sensor 

(HIGHBAY-MS)

DAYLIGHT PRIORITY

1. Rotate the sealing cover (cap) counter-clockwise 

until it cannot be rotated any further. Pull it outwards 

and remove.

With Daylight Priority Function, HIGHBAY-MS is able to 

differentiate artificial light brightness from natural light after 

installed inside the fixture, and automatically turn off light when 

ambient brightness exceeds the preset Lux level.

Precondition of Daylight Priority:
1.  Stand-by period is +∞

2. Stand-by dimming level is on 10%, 20% or 30%

3. Daylight threshold is on 30Lux, 50Lux, 80Lux or 120Lux

4. The installation should be carried out without 

power supply connected. Recheck and other relevant 

tests should be conducted after completion of the 

installation. After correct installation, the marking 

point of the Sensor shall be in the same direction as 

the interface direction arrow.

2. Please store the removed sealing cover (cap) for 

future use.

3. Place the plug part of the Sensor on the expansion 

interface and find the only installation position through 

360° rotation. When rotating to the correct position, 

the module will be embedded downward. You can 

also refer to the direction guide arrow, and then rotate 

clockwise to complete the installation. When it cannot 

rotate any further, it is locked.

INSTALLATION

Summary of Contents for HIGHBAY-MS

Page 1: ...y Default 5s Daylight Threshold 2 10 30 50 80 120Lux or Disable Factory Default Disable Stand by Period 0s 10s 30s 1min 5min 10min 30min 60min Factory Default 0s Stand by Dimming Level 10 20 30 50 Factory Default 10 Maximum Mounting Height Max 12m Ceiling Mounted Maximum Detection Range Max ø12m Ceiling Mounted Motion Detection 0 5 1m s Operating Temperature 20 C to 60 C IP Rating IP65 TECHNICAL S...

Page 2: ...Stand by period is 2 Stand by dimming level is on 10 20 or 30 3 Daylight threshold is on 30Lux 50Lux 80Lux or 120Lux 4 The installation should be carried out without power supply connected Recheck and other relevant tests should be conducted after completion of the installation After correct installation the marking point of the Sensor shall be in the same direction as the interface direction arro...

Page 3: ...sor keeps light ON 100 for holdtime After holdtime sensor dims light to standby dimming level for standby period The sensor turns OFF light automatically after the standby period when there s no motion detected With insufficient daylight the sensor turns light ON when motion gets detected The sensor keeps light ON for holdtime period after motion leaves The sensor turns OFF light automatically aft...

Page 4: ...ns the highest sensitivity and longest distance Press it specific icon on the screen will blink and press the buttons to adjust Hold Time The period that light will stay illuminated 100 after no motion s detected Press it specific icon on the screen will blink and press the buttons to adjust Daylight Threshold The preset Lux level to compare with ambient brightness when motion gets detected Press ...

Page 5: ... then be kept afte 5S Each press will make sensor dim down light then back to100 it means remote signal has been well received ON OFF Mode 1 ON OFF button to turn on the light 2 Press button to dim light directly it dims from 10 to 100 DIMMING Mode 1 ON OFF button to turn on the light 2 SCENE button to start programming 3 POWER button 4 buttons to dim light but it only dims from 60 to 100 50 is on...

Reviews: