background image

For more information

www.haneco.com.au

1300 001 LED

Art11102022

PAGE 1

MOTION SENSOR & REMOTE

HANECO LIGHTING USER GUIDE

HIGHBAY-MS + HIGHBAY-REMOTE

 FOR SKYLUX-G4/SL/SP AND BENZINA-G2

Microwave Motion Sensor 

(HIGHBAY-MS)

ON/OFF Control

Detection Area

Remote Control

Daylight Sensor

Stand-by Period

10-12m Highbay

Hold Time

Stand-by Dimming Level

Operating Voltage:

10.5-15V d.c. <30mA

Output:

DIM 0-10V

Standby Consumption:

<30mA

Microwave Frequency: 

5.8GHz ± 75MHz

Microwave Power:

<0.3mW

Daylight Priority Function:

120/80/50/30Lux   |   Dimming: 10/20/30%

Factory Default: Disable

Detection Area Setting:

25/50/75/100%

Factory Default: 100%

Hold Time: 

5s/30s/1min/3min/5min/10min/20min/30min

Factory Default: 5s

Daylight Threshold: 

2/10/30/50/80/120Lux (or Disable)

Factory Default: Disable

Stand-by Period:

0s/10s/30s/1min/5min/10min/30min/60min +∞

Factory Default: 0s

Stand-by Dimming Level: 

10/20/30/50%

Factory Default: 10%

Maximum Mounting Height:

Max. 12m Ceiling Mounted

Maximum Detection Range:

Max. ø12m Ceiling Mounted

Motion Detection:

0.5 ~ 1m/s

Operating Temperature:

-20°C to +60°C

IP Rating:

IP65

TECHNICAL SPECIFICATIONS

DETECTION PATTERN

Highest mounting height is 12m.

This figure indicates the maximum distance at the highest 

mounting height with 100% sensitivity.

Well Detected Area

Possible Detected Area

The Motion Sensor must be installed by a professional electrician. Switch power off prior to installation. Ensure input 

voltage conforms to the voltage range of product. Please read these instructions carefully before using this product 

and keep for future reference.

  WARNING

Summary of Contents for HIGHBAY-MS

Page 1: ...y Default 5s Daylight Threshold 2 10 30 50 80 120Lux or Disable Factory Default Disable Stand by Period 0s 10s 30s 1min 5min 10min 30min 60min Factory Default 0s Stand by Dimming Level 10 20 30 50 Factory Default 10 Maximum Mounting Height Max 12m Ceiling Mounted Maximum Detection Range Max ø12m Ceiling Mounted Motion Detection 0 5 1m s Operating Temperature 20 C to 60 C IP Rating IP65 TECHNICAL S...

Page 2: ...Stand by period is 2 Stand by dimming level is on 10 20 or 30 3 Daylight threshold is on 30Lux 50Lux 80Lux or 120Lux 4 The installation should be carried out without power supply connected Recheck and other relevant tests should be conducted after completion of the installation After correct installation the marking point of the Sensor shall be in the same direction as the interface direction arro...

Page 3: ...sor keeps light ON 100 for holdtime After holdtime sensor dims light to standby dimming level for standby period The sensor turns OFF light automatically after the standby period when there s no motion detected With insufficient daylight the sensor turns light ON when motion gets detected The sensor keeps light ON for holdtime period after motion leaves The sensor turns OFF light automatically aft...

Page 4: ...ns the highest sensitivity and longest distance Press it specific icon on the screen will blink and press the buttons to adjust Hold Time The period that light will stay illuminated 100 after no motion s detected Press it specific icon on the screen will blink and press the buttons to adjust Daylight Threshold The preset Lux level to compare with ambient brightness when motion gets detected Press ...

Page 5: ... then be kept afte 5S Each press will make sensor dim down light then back to100 it means remote signal has been well received ON OFF Mode 1 ON OFF button to turn on the light 2 Press button to dim light directly it dims from 10 to 100 DIMMING Mode 1 ON OFF button to turn on the light 2 SCENE button to start programming 3 POWER button 4 buttons to dim light but it only dims from 60 to 100 50 is on...

Reviews: