USER MANUAL
|
19
EN
A
B
C A U S E
S O L U T I O N
SWITCH
Problem:
If the lift is not moving in either direction, there is no code on the
diagnostic display
Cause:
The lift may be switched off.
Solution:
Turn the lift on.
Problem:
the lift travels in one direction only and the display shows a “
4/6
”.
Cause:
there is an obstacle between the lift and the stairs.
Solution:
move the lift in the opposite direction {A} and remove the obstacle {B}.
C A U S E
S O L U T I O N
OBSTACLE