MilkyWay
MilkyWay Handbook • Version 3 - 20140616 © Handicare AB
4: Rail systems with full room coverage - (x-y)/traverse systems / 36
4.4.4: Heights, systems with transition gates
A single transition gate connected to an (x-y)/traverse system must be lowered to level with the cross-rail. This is
done by means of pendants 50400164 or 50400165. 504000164 is normally used when the fixed rail is Rail 64 (A)
and 50400165 is normally used when the fixed rail is Rail 120 or Rail 160 (B).
* Free height over the cross-rail, if supported with a bolt-on rail, see 4.2: Supported cross-rails.
In both examples, the fixed rail is fixed to the ceiling by means of a ceiling bracket, 50400319, not shown here. Wall
brackets cannot be used to fix this rail near the transition gate, as a minimum distance of 125 mm is required to the
wall (A).
The pendants (50400164 or 50400165) are adjustable, see ranges below.
h min.: 115 mm
h norm.: 122 mm
h max.: 135 mm
h min.: 160 mm
h norm.: 168 mm
h max.: 180 mm
*94
*38
A