75
The batteries are not charging
The red wire of the charge contacts is the “+”, the black wire is the “-”.
When looking at the unit from the front side:
the carbon brush on the right is the “+”, the one on the left is the “-”.
Check the voltage on the charging station of the rail:
The voltage is “0 V=”
•
No network voltage or plug is not in the socket
•
The battery charger is defective
•
Wire break in the cables from the charge stations
•
Jack plug in the rail has loosened
Check the voltage on the charging station of the rail:
The voltage is around “27,6 V=”
•
Wire break between K3-7/K7-2 and the carbon brush
•
Wire break between K3-8/K8-2 and the carbon brush
•
Earth short at K3-7, K3-8
•
No contact between charging point and carbon brushes, check the plastic pin
11
|