15
2. CLOCK
Test Point
Function
Value
JP2-4
Line Sync
5 V 60 Hz, 50% Duty Cycle
square wave
JP3-8
Line Sync
5V 60 Hz pulse normally
low
Active on JP2-4 rising
edge
U5-38
Microprocessor 4MHz +/- 440 Hz
Clock
3. SYNC
Test Point
Function
Value
JP3-7
Sync lost
5V active when sync lost
JP3-6
Search
5V active when searching
4. ADJUST
Adjust R22 to set the intensity of the LEDs