H&H CS-652 Operation Manual Download Page 10

 

 

  CS-652  operation  manual

 

 

 

issue 2 14.01.17                                                                                                               

                        P.9 of 14

 

Preparation Before Main Power Connected 

 
 

1.

 

Compress air connection 

 

Since the heating plate will go up after compress air connected, the cable ties on the heating 
plate and the working table should be removed first. 

 
2.

 

Main power connection 
 
The main power cable with plug is located at the back of the machine, plug into the main power 
supply socket. 

 
3.

 

Foot switch connection 

 

The foot switch socket is located at the back of the machine, plug in the foot switch connector 
and tighten the screws. 
 
 

>

 Operation Mode Selection

 

 
 

The machine has two operation modes: 

 

A.

 

Manual Push Button Mode – Press both the left & right start buttons at the front, the heating 
plate goes down, the timer starts to countdown. Once the timer is up or when you press the 
cancel button at the middle, the heating plate goes up. 

B.

 

Pedal Control Mode – Step on the left foot switch, the heating plate goes down, after move 
away the foot, the timer starts to countdown. When the countdown is completed or you step 
into the right pedal, the heating plate goes up. 

 

 

 

 

 

 

 

 

 

 

 
                                                                Pedal Switch 

 

 

Summary of Contents for CS-652

Page 1: ...e service hh com hk t 852 24813068 f 852 24813727 Room 1117 11 F Asia Trade Centre 79 Lei Muk Road Kwai Chung N T Hong Kong CS 652 Pneumatic Flat Press Machine Operation Manual is powered by H H Asia...

Page 2: ...ifications Machine Components Control Console Preparation Before Main Power Connected Operation Mode Selection Machine Operation Machine Setting Control Panel Control Panel General Display Temperature...

Page 3: ...regard to Safety Please observe these safety tips for safe efficient an injury free operation of your equipment By strictly following all instruction contained in this manual you will certainly obtai...

Page 4: ...CS 652 operation manual issue 2 14 01 17 P 3 of 14 Precautions with regard to Safety cont...

Page 5: ...CS 652 operation manual issue 2 14 01 17 P 4 of 14 Name Plate...

Page 6: ...r processing the flat press products in the market today Built on digital control platform and designed for the professional users Operators are recommended to have basic knowledge and skill in heat p...

Page 7: ...on 1000 W Compressed Air 0 4 Mpa Heat Temperature Range Room Temperature 260O C Press Duration 1 999 second minute or hour Heat Press Size 8 X 6 Lower Platform Size 8 X 6 Overall Dimensions 520mm L x...

Page 8: ...ess pressure adjusting knot for the cylinder 2 control console 3 heating plate pressing head 4 safety protective bar 5 lower platform 6 machine base 7 start buttons must press both left right buttons...

Page 9: ...ssue 2 14 01 17 P 8 of 14 Control Console 1 Main Power Switch On Off the Main Power 2 Led Light Switch On Off the Led Light 3 Heater Switch On Off the Heater 4 Control Panel Set the heat temperature s...

Page 10: ...ocket is located at the back of the machine plug in the foot switch connector and tighten the screws Operation Mode Selection The machine has two operation modes A Manual Push Button Mode Press both t...

Page 11: ...step on the left foot switch once or press the start buttons at the front the heating plate will goes down The timer will be triggered simultaneously After the countdown finished the heating plate wil...

Page 12: ...rol Panel 1 PV Field processing temperature 2 SV Set target temperature 3 SET Select different settings 4 OUT1 decrease the set point 5 OUT2 increase the set point Control Panel General Display Genera...

Page 13: ...ustment Press the 3 SET once again the display will alike the below diagram PV will show with St and SV will show the preset press time setting You can press the OUT1 to decrease or OUT2 to increase t...

Page 14: ...Thermocouple connection is loosen Check and tighten the connection Temperature controller malfunction Replace the circuit board in the control box Thermocouple extension cable short circuit Check the...

Page 15: ...7 P 14 of 14 Appendix A Control Circuit Schematic Diagram Cancel switch 24V 24V Safety Bar On Off Right Foot Switch On Off Contactor Contact Point Left Foot Swi tch On Off Start button left Start butt...