![H&H AI-002 Operation Manual Download Page 49](http://html1.mh-extra.com/html/handh/ai-002/ai-002_operation-manual_3067827049.webp)
AI-002 operation manual
Issue 1 21.09.09 display version 13 . main controller version 69 . servo version 61
P.48 of 59
Appendix D . Tape Start, Tape Middle, Tape End Parameters
> Tape Start Program (cont.)
> Tape Start Program > start of tape nozzle penetration speed
This setting controls the speed of nozzle moving towards the upper roller during a tape start. A
tape start operation only happens once within the same tape. A smaller setting will increase the
time it takes for the nozzle to move towards the upper roller during a start, but this will provide a
more evenly heated tape start.