background image

12 - 2

3800i/3800r User’s Guide

3800r Depth of Field

Minimum Bar 
Width

Maximum Near 
Field

Minimum Far Field 
(no ambient lighting)

13 mil 100% UPC

1 in (2.5 cm)

24 in (61 cm)

7.5 mil Code 39

4 in (10 cm)

14 in (36 cm)

10 mil Code 39

2 in (5 cm)

18 in (46 cm)

13 mil Code 39

1 in (2.5 cm)

24 in (61 cm)

15 mil Code 39

1 in (2.5 cm)

28 in (71 cm)

20 mil Code 39

1 in (2.5 cm)

36 in (91 cm)

55 mil Code 39

4 in (10.2 cm)

44 in (112 cm)

Summary of Contents for IMAGETEAM 3800i

Page 1: ...3800i Industrial Handheld Linear Imager 3800r Retail Commercial Handheld Linear Imager User s Guide...

Page 2: ...rt of Hand Held Products Hand Held Products shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishin...

Page 3: ...f and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Page 4: ...cUL listed UL1950 and CSA 22 2 No 950 LED Safety Statement This device has been tested in accordance with EN60825 1 LED safety and has been certified to be under the limits of a Class 1 LED device Aim...

Page 5: ...0i packaging for patent information Solids and Water Protection The 3800i has a rating of IP54 immunity of windblown dust penetration and splashing water The 3800r has a rating of IP41 immunity of for...

Page 6: ......

Page 7: ...the Standard Product Defaults 1 7 Plug and Play 1 7 Keyboard Wedge Connection 1 8 Laptop Direct Connect 1 8 RS 232 1 8 Wand Emulation Plug Play 1 9 IBM 4683 Ports 5B 9B and 17 Interface 1 9 Connectin...

Page 8: ...Good Read Indicators 3 1 Beeper Good Read 3 1 Beeper Volume Good Read 3 1 Beeper Pitch Good Read 3 1 Beeper Duration Good Read 3 2 LED Good Read 3 2 Number of Beeps Good Read 3 2 Good Read Delay 3 3...

Page 9: ...ions 4 4 Function Code Transmit 4 4 Intercharacter Interfunction and Intermessage Delays 4 4 Intercharacter Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage Delay...

Page 10: ...abar Concatenation 7 4 Codabar Message Length 7 4 Code 39 7 5 Code 39 Start Stop Characters 7 5 Code 39 Check Character 7 6 Code 39 Message Length 7 6 Code 39 Append 7 7 Code 32 Pharmaceutical PARAF 7...

Page 11: ...UPC A Check Digit 7 18 UPC A Number System 7 18 UPC A Addenda 7 19 UPC A Addenda Required 7 19 UPC A Addenda Separator 7 19 UPC A EAN 13 with Extended Coupon Code 7 20 UPC E 7 20 UPC E0 and UPC E1 Ex...

Page 12: ...th 7 30 EAN UCC Emulation 7 30 China Post Code 7 30 Korea Post Code 7 31 Korea Post Message Length 7 31 PosiCode 7 32 PosiCode Message Length 7 33 Trioptic Code 7 33 Codablock F 7 33 Codablock F Messa...

Page 13: ...ple Commands 11 2 Responses 11 2 Examples of Query Commands 11 3 Trigger Commands 11 4 Resetting the Standard Product Defaults 11 4 Menu Commands 11 5 Chapter 12 Product Specifications 3800r Product S...

Page 14: ...4 1 Online Product Service and Repair Assistance 14 2 Technical Assistance 14 2 Online Technical Assistance 14 2 Limited Warranty 14 2 Appendix A Appendix A Symbology Chart A 1 ASCII Conversion Chart...

Page 15: ...g range durability and the ability to read poor quality bar codes Linear imaging technology is defined by a bright and sharply focused aiming line high resolution imaging and fast reading speed The 38...

Page 16: ...aces The chart below lists the 3800i scanner models SR indicates Standard Range linear optics If the product number has the number one 1 as the last character the unit contains the aimer beam option e...

Page 17: ...ter 6 for programming information regarding Secondary Interfaces The chart below lists the 3800r scanner models SR indicates Standard Range linear optics Models Primary Interfaces Secondary Interfaces...

Page 18: ...1 4 3800i 3800r User s Guide 3800i 3800r Scanner Identification...

Page 19: ...3800i 3800r User s Guide 1 5 3800i Scanner with aimer beam option Identification...

Page 20: ...t mode The following is an example of a keyboard wedge connection 1 Turn off power to the terminal computer 2 Disconnect the keyboard cable from the back of the terminal computer 3 Connect the appropr...

Page 21: ...the imager at an appropriate distance from the target pull the trigger and center the aiming line on the symbol Resetting the Standard Product Defaults If you aren t sure what programming options are...

Page 22: ...R suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect b...

Page 23: ...sets the terminal ID to 64 These Plug Play bar codes also set the Transmission Rate to 25 inches per second Output Polarity to black high and Idle State to high If you want to change the terminal ID o...

Page 24: ...es programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR 2 Interface Symbology Suffix EAN 8...

Page 25: ...ls in the back of this manual Note The following USB Plug and Play codes are supported on specific models Refer to 3800r Models and on page 1 3 to determine if this interface applies to your scanner F...

Page 26: ...m the imager for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes adds a CR and selects the terminal ID USB PC Keyboard 124 USB Macintosh Keyboard 125 USB PC Japanese Keyboard 134 Symbol...

Page 27: ...If you are using a Microsoft Windows PC you will need to download a driver from the Hand Held Products website www handheld com The driver will use the next available Com Port number Apple Macintosh c...

Page 28: ...he existing serial cable from the computer 3 Connect the appropriate interface cable to the scanner Note For the scanner to work properly you must have the correct cable for your type of computer 4 Pl...

Page 29: ...rminal ID 050 and follow the instructions on page 2 1 Set the port to which you want the scanned data to transmit Port 1 corresponds to P1 on the output cable and Port 2 corresponds to P2 on the outpu...

Page 30: ...1 16 3800i 3800r User s Guide...

Page 31: ...ual to program the scanner for your terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID bar code then 0 0 3 from the Pro...

Page 32: ...M 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Handheld Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM Thinkpad 360 CSE 340 750...

Page 33: ...nd Play bar codes on page 1 12 to program these interfaces rather than scanning the terminal ID listed in this table Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 US...

Page 34: ...de below to program the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Denmark France...

Page 35: ...Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the Caps...

Page 36: ...Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Refer to Keyboard Function Relationships page 8 1 for CTRL ASCII Values Default Off Turbo Mode The scanner send...

Page 37: ...uide 2 7 Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Automatic Direct Connect Mode On Automatic Dire...

Page 38: ...board into the power tap on the scanner cable 4 Plug the power tap into the mouse or keyboard port 5 Plug the serial connector into the serial port on your computer Tighten the two screws to secure th...

Page 39: ...232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115 200 300 2400 600 1200 4800...

Page 40: ...s For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit...

Page 41: ...change other parameters in addition to changing the terminal ID Please refer to Wand Emulation Plug Play on page 1 9 for further information In Wand Emulation mode the imager decodes the bar code the...

Page 42: ...is limited by the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or reversed...

Page 43: ...h the scanner is connected Default Idle High Wand Emulation Note Changing primary wand emulation settings also changes the secondary wand emulation settings see Secondary Code 39 Wand Emulation on pag...

Page 44: ...lt 50ms Overall Checksum Note This option is not applicable to Laser Emulation Raw Output see Secondary Laser Emulation on page 6 3 When this option is turned on a computed check character is added at...

Page 45: ...cation All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High for the 3800i M...

Page 46: ...rogrammed from 1 9 The same number of beeps will be applied to the beeper and LED in response to a good read For example if you program this option to have five beeps there will be five beeps and five...

Page 47: ...rigger You can activate the scanner either by pressing the trigger or using a serial trigger command see Trigger Commands on page 11 4 When in manual trigger mode the scanner scans until a bar code is...

Page 48: ...bar code below There is a delay of up to one second in operation when the scanner is first triggered but there is no delay when operating in low power time out mode Note Manual Trigger Low Power canno...

Page 49: ...g a hands free mode the imager changes to manual trigger mode You can set the time the imager should remain in manual trigger mode by setting the Hands Free Time Out Once the time out value is reached...

Page 50: ...Specified Reread Delay If you want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then...

Page 51: ...n t turn on until the delay time is over User Specified Aimer Beam Delay If you want to set your own length for the duration of the delay scan the bar code below then set the time out by scanning digi...

Page 52: ...d of view so the scanner reads only the bar code you want When centering is turned on the scanner only reads codes that intersect or are contained within the centering window you set up At least part...

Page 53: ...ge from 1 to 100 Example If you have two bar codes next to one another and the centering window is set to 40 left edge and 60 right edge only the bar code that intersects that window will be decoded 2...

Page 54: ...options Note You must hold the trigger while reading each bar code in a sequence To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output Sequence page 3 11 2 Code I D On the Symb...

Page 55: ...mpt to get the output data to conform to an edited sequence but if it cannot the scanner transmits all output data to the host device as is When the output sequence is Off the bar code data is output...

Page 56: ...28 9999 code length that must match for Code 128 9999 all lengths 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 9999 code length that...

Page 57: ...r third code Multiple Symbols Note This feature does not work when the scanner is in Low Power mode When this programming selection is turned On it allows you to read multiple symbols with a single pu...

Page 58: ...page 5 5 The hex code for the No Read symbol is 9C Video Reverse Video Reverse is used to allow the scanner to read bar codes that are inverted The Off bar code below is an example of this type of ba...

Page 59: ...mbologies The following illustration shows the breakdown of a message string Points to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wi...

Page 60: ...character Step 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading ba...

Page 61: ...Hex value from the Symbology Chart included in the Appendix A for the symbology from which you want to clear the pre fix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart inside t...

Page 62: ...is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information charact...

Page 63: ...er Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below...

Page 64: ...ng Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below...

Page 65: ...ID Universal Length 5 Universal Term ID Actual Code ID Actual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Univer...

Page 66: ...ual to save your entries Other Programming Selections Clear One Data Format This deletes one data format for one symbology If you are clearing the primary format scan 0 from the Programming Chart insi...

Page 67: ...f characters the cursor should be moved back F7 Move the cursor to the beginning of the data string Syntax F7 EA Move the cursor to the end of the data string Syntax EA Search Commands F8 Search ahead...

Page 68: ...nes replacement characters continuing through zz1 and zz2 E5 Terminates character replacement Syntax E5 FE Compare character in current cursor position to the character xx If char acters are equal inc...

Page 69: ...ot capability to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary format or...

Page 70: ...5 6 3800i 3800r User s Guide...

Page 71: ...it contains the aimer beam option e g 3000iSR001 3800r Models Models Primary Interfaces Secondary Interfaces 3800iSR00XE TTL Level 232 Laser Emulation 3800iSR03XE True RS 232 True RS 232 serial wedge...

Page 72: ...te or parity while in primary or secondary mode will affect both interfaces If you want to change the RS 232 settings refer to the Connecting the Scanner with RS 232 Serial Port section on pages 2 8 t...

Page 73: ...raw data edges to the host for host decoding This also sets the transmission rate to 36 scans per second and the polarity to white high When you scan the following bar code the scanner decodes and re...

Page 74: ...e device to which the scanner is connected Default Idle High Secondary Trigger Mode Manual Trigger You must press the scanner trigger to scan When not scanning idle power is maintained Default Manual...

Page 75: ...t The Automatic Trigger and Presentation Modes are referred to as hands free modes If the imager s trigger is pulled when using a hands free mode the imager changes to manual trigger mode You can set...

Page 76: ...6 6 3800i 3800r User s Guide...

Page 77: ...ly a particular symbology scan All Symbologies Off followed by the On symbol for that particular symbology All Symbologies Korea Post Code China Post Code Matrix 2 of 5 Codabar UPC A EAN 13 with Exten...

Page 78: ...read EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a...

Page 79: ...ter No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Co...

Page 80: ...ed Default On Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codaba...

Page 81: ...Code 39 Settings Code 39 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Defau...

Page 82: ...ned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data De...

Page 83: ...does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The scanner transmits the appended data when it reads...

Page 84: ...airs P through Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D...

Page 85: ...ase scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code from t...

Page 86: ...f 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the mes...

Page 87: ...play with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar...

Page 88: ...of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 M...

Page 89: ...r codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default Al...

Page 90: ...additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check d...

Page 91: ...communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling...

Page 92: ...is expecting If this is the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the valu...

Page 93: ...ymbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the bar codes below to chan...

Page 94: ...specify whether the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beg...

Page 95: ...ddenda Required is set to on the scanner will only read UPC A bar codes that have addenda Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from th...

Page 96: ...nded Coupon Code Default On UPC E Default All UPC E Settings UPC E0 and UPC E1 Most U P C bar codes lead with the 0 number system For these codes use the UPC E0 selection If you need to read codes tha...

Page 97: ...ead UPC E bar codes that have addenda Default Not Required UPC E0 and UPC E1 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda...

Page 98: ...ata but the unit can be programmed so it will not transmit it Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit...

Page 99: ...13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Addenda Required is set to on t...

Page 100: ...nda When turned off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code on page 7 20 ISBN Translate This...

Page 101: ...ld be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit...

Page 102: ...there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On MSI Default All MSI Settings MSI MSI Check Character Different types of c...

Page 103: ...ead MSI bar codes printed with the specified type check character but will not transmit the check character with the scanned data MSI Message Length Scan the bar codes below to change the message leng...

Page 104: ...odes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 RSS 14 Default All RSS 14 S...

Page 105: ...3800i 3800r User s Guide 7 29 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings RSS Expanded On Off On Off...

Page 106: ...or RSS Composite symbol EAN UCC data carriers include UPC A and UPC E EAN 13 and EAN 8 ITF 14 UCC EAN 128 and EAN UCC RSS and Composites If UCC EAN 128 Emulation is selected the AIM Symbology Identif...

Page 107: ...the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Korea Post Code Default All Korea Post Code Sett...

Page 108: ...mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 PosiCode Default All PosiCode Settings PosiCode A and B You have to have PosiCode A and B on to read any of the PosiCode symbologies M...

Page 109: ...l information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Trioptic Code Trioptic Code is used for labeling magnetic storage media Note If you are going to scan Code 32 Pharma...

Page 110: ...2048 Minimum Default 1 Maximum Default 2048 Code 16K Default All Code 16K Settings Code 16K Code 16K Message Length Scan the bar codes below to change the message length Refer to Message Length on pag...

Page 111: ...de 49 Code 49 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Max...

Page 112: ...7 36 3800i 3800r User s Guide...

Page 113: ...hat can be used with the scanner Refer to page 2 6 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08...

Page 114: ...L column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany...

Page 115: ...Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E In...

Page 116: ...0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Pri...

Page 117: ...A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Esc...

Page 118: ...04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Pr...

Page 119: ...he bar code below to output the current software revision unit serial number and other product information Show Data Format Scan the bar code below to show current data format settings Resetting the S...

Page 120: ...Note Connect the imager using RS 232 cables Scan the bar code below and the unit will communicate in RS 232 mode allowing it to work with Visual Xpress The imager reverts to the original or reprogramm...

Page 121: ...odes and display the bar code data in a window Scan Data lets you send serial commands to the imager and receive imager response that can be seen in the Scan Data window The data displayed in the Scan...

Page 122: ...ess 5 When prompted select Save File and save the files to the c windows temp directory 6 Once you have finished downloading the file exit the web site 7 Using Explorer go to the c windows temp file a...

Page 123: ...appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII ch...

Page 124: ...not be used because it is ignored by the device Data Field Usage When a query is used in place of the Data field the query applies only to the specific command identified by the Tag and SubTag fields...

Page 125: ...ENA1 ACK This response indicates that the default setting for Codabar Coding Enable CBRENA is 1 or on Example Example 3 What is the device s current setting for Codabar Coding Enable Enter cbrena Resp...

Page 126: ...vate SYN U CR The scanner scans until a bar code has been read until the deactivate com mand is sent or until the serial time out has been reached see Read Time Out on page 3 4 for a description and t...

Page 127: ...TY3 2 4 Germany Austria KBDCTY4 2 4 Great Britain KBDCTY7 2 4 Italy KBDCTY5 2 4 Norway KBDCTY9 2 4 Spain KBDCTY10 2 4 Switzerland KBDCTY6 2 4 Keyboard Style Regular KBDSTY0 2 5 Caps Lock KBDSTY1 2 5 S...

Page 128: ...rity Odd 232WRD6 2 10 7 Data 2 Stop Parity Even 232WRD4 2 10 7 Data 2 Stop Parity None 232WRD1 2 10 7 Data 2 Stop Parity Odd 232WRD7 2 10 8 Data 1 Stop Parity Even 232WRD5 2 10 8 Data 1 Stop Parity No...

Page 129: ...80 WNDBLK3 2 13 Wand Emulation Delay Between Blocks 5ms WNDDLY0 2 14 50ms WNDDLY1 2 14 150ms WNDDLY2 2 14 500ms WNDDLY3 2 14 Wand Emulation Overall Checksum Off WNDCHK0 2 14 On WNDCHK1 2 14 Output Sel...

Page 130: ...Out 0 300 000 ms 300 000 TRGSTO 3 4 Manual Trigger Low Power TRGMOD2 3 4 Low Power Time Out 0 300 seconds 120 TRGLPT 3 4 Automatic Trigger TRGMOD1 3 4 Presentation Mode TRGMOD3 3 5 Hands Free Time Out...

Page 131: ...d On SHWNRD1 3 13 Off SHWNRD0 3 13 Video Reverse On VIDREV1 3 13 Off VIDREV0 3 13 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Add Prefix PREBK2 4 3 Clear One Prefix PRE...

Page 132: ...IFTYP0 6 2 Secondary Code 39 Wand Emulation Same Code Format 2IFTYP64 6 2 Code 39 Format 2IFTYP61 6 2 Secondary Laser Emula tion Laser Emulation Same Code Output PAPHLC 6 3 Laser Emulation Raw Output...

Page 133: ...CT1 7 4 Require CBRCCT2 7 4 Codabar Message Length Minimum 2 60 4 CBRMIN 7 4 Maximum 2 60 60 CBRMAX 7 4 Code 39 Default All Code 39 Settings C39DFT 7 5 Code 39 Off C39ENA0 7 5 On C39ENA1 7 5 Code 39 S...

Page 134: ...essage Length Minimum 0 80 0 C93MIN 7 11 Maximum 0 80 80 C93MAX 7 11 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 7 12 Straight 2 of 5 Industrial Off R25ENA0 7 12...

Page 135: ...catenation On ISBENA1 7 15 Off ISBENA0 7 15 Code 128 Message Length Minimum 0 80 0 128MIN 7 16 Maximum 0 80 80 128MAX 7 16 Code 128 Code Page Code 128 Code Page 128DCP 7 16 Code 128 Function Code Tran...

Page 136: ...DS1 7 19 UPC E Default All UPC E Settings UPEDFT 7 20 UPC E0 Off UPEEN00 7 20 On UPEEN01 7 20 UPC E1 Off UPEEN10 7 20 On UPEEN11 7 20 UPC E Expand Off UPEEXP0 7 21 On UPEEXP1 7 21 UPC E Check Digit Of...

Page 137: ...13ADS1 7 24 ISBN Translate Off E13ISB0 7 24 On E13ISB1 7 24 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 7 25 EAN JAN 8 Off EA8ENA0 7 25 On EA8ENA1 7 25 EAN JAN 8 Check Digit Off EA8CKX0 7 25 On EA...

Page 138: ...Settings RSSDFT 7 28 RSS 14 Off RSSENA0 7 28 On RSSENA1 7 28 RSS Limited Default All RSS 14 Limited Settings RSLDFT 7 29 RSS Limited Off RSLENA0 7 29 On RSLENA1 7 29 RSS Expanded Default All RSS 14 E...

Page 139: ...osiCode Msg Length Minimum 2 80 4 POSMIN 7 33 Maximum 2 80 48 POSMAX 7 33 Trioptic Code Off TRIENA0 7 33 On TRIENA1 7 33 Codablock F Default All Codablock F Set tings CBFDFT 7 33 Codablock F Off CBFEN...

Page 140: ...11 18 3800i 3800r User s Guide...

Page 141: ...aw Max Scanning Standby Inrush Low Power 3800rSR000E Model 5Vdc 235mA 68mA 350mA 100 A 12Vdc 142mA 48mA 3800rSR050E Model 5Vdc 235mA 68mA 350mA 100 A 12Vdc 127mA 48mA 3800rSR030E Model 5Vdc 210mA 60mA...

Page 142: ...Field no ambient lighting 13 mil 100 UPC 1 in 2 5 cm 24 in 61 cm 7 5 mil Code 39 4 in 10 cm 14 in 36 cm 10 mil Code 39 2 in 5 cm 18 in 46 cm 13 mil Code 39 1 in 2 5 cm 24 in 61 cm 15 mil Code 39 1 in...

Page 143: ...age Requirements 4 5 to 12VDC at scanner Current Draw Max Scanning Standby Inrush Low Power 3800iSR00XE Model 5Vdc 235mA 68mA 350mA 100 A 12Vdc 142mA 48mA 3800iSR05XE Model 5Vdc 235mA 68mA 350mA 100 A...

Page 144: ...g Min Far Field 300 Lux lighting 13 mil 100 UPC 2 5 in 6 4 cm 26 in 66 cm 28 in 71 cm 7 5 mil Code 39 6 5 in 16 5 cm 14 in 36 cm 15 in 38 cm 15 mil Code 39 2 5 in 6 4 cm 30 in 76 2 cm 31 in 78 7 cm 20...

Page 145: ...Start of scan Digital bar code data output Turn on good read LED or beeper N C Trigger signal to decoder 9 Pin Type D Female connects to your terminal Laser enable Supply ground Cord shield 5 Volt pow...

Page 146: ...board Wedge 10 Pin RJ41 Modular Plug connects to the scanner handle 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables on page...

Page 147: ...ndle 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 6 Bar code data output 7 Supply power input Refer to tables on page 12 1 and page 12 3 8 9 10 Bar code data outpu...

Page 148: ...ects to the scanner handle 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 Supply power...

Page 149: ...3800i 3800r User s Guide 12 9 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the scanner handle 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data...

Page 150: ...12 10 3800i 3800r User s Guide...

Page 151: ...th a soft cloth or lens tissue dampened with water or a mild detergent water solution or alcohol If a detergent solution is used rinse with a clean lens tissue dampened with water only The scanner s h...

Page 152: ...terface cable To Replace the 3800r Interface Cable 1 Turn the power to the host system OFF 2 Disconnect the scanner s cable from the terminal or computer 3 Locate the small hole on the side of the sca...

Page 153: ...to the opening and press firmly The connector is keyed to go in only one way and will click into place 8 If the cord lock is used screw it back in place over the cord Troubleshooting The scanner autom...

Page 154: ...the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scanner with the correct Plug and Play or Terminal selection bar code See Chapter 1 and Chapter 2 T...

Page 155: ...Corporate Offices Telephone 800 782 4263 Option 3 Fax 704 566 6015 E mail naservice handheld com America Latina Hand Held Products America Latina Tel fono 239 263 7600 Fax 239 263 9689 E mail laservic...

Page 156: ...ne Technical Assistance You can also access technical assistance online at www handheld com Limited Warranty Hand Held Products Inc Hand Held Products warrants its products to be free from defects in...

Page 157: ...IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT IN NO EVENT SHALL Hand Held Products BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF...

Page 158: ...14 4 3800i 3800r User s Guide...

Page 159: ...e ID AIM ID Hex ID China Post Q X0 51 Straight 2 of 5 IATA f Rm 66 Codabar a Fm 61 Interleaved 2 of 5 e lm 65 Codablock F q Om 71 Korea Post X0 3F Straight 2 of 5 Industrial f Rm 66 Matrix 2 of 5 m X0...

Page 160: ...29 73 49 l 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4...

Page 161: ...139 8B 171 AB 203 CB 235 EB 140 8C 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 91 177 B1 209 D1 241 F1 146...

Page 162: ...tion is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replac...

Page 163: ......

Page 164: ......

Page 165: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E...

Page 166: ...Sample Symbols Code 93 123456 9 Straight 2 of 5 Industrial 123456 Matrix 2 of 5 6543210 RSS 14 01 00123456789012 Code 39 Codabar BC321 A13579B...

Page 167: ...ogramming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save 0 2 6 1 7 5 4 3 8...

Page 168: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3800i r UG Rev A 5 06...