
4
management system, and each product can reach the same standard as an EU model tested sample. According to
different conditions of conformity assessment the appendix of ATEX 2014/34/EU also regulates corresponding QA
requirements. The confirmation of requirement of the above mentioned QA system is supervised by EU designated
authorities, and the so called QA system is not only the field covered by ISO 9001.
Explosion Proof
Regulatory standard
Directive 2014/34/EU
Directive 1999/92/EC
Applicable standard
Equipments
Working Place
Attribution of
responsibility
Manufacturer
User
Range of
responsibility
Model certification, Quality
assurance
Risk assessment, Grading of dangerous zone, Correctly use of
explosion proof equipments
+
=
Manufactures
Directive(2014/34/EU)
End Users'
Directive(1999/92/EC)
Explosion Protection
1.2 Zone Classification
1.3 Gas Group
Zone or
division
Definition
Zone0(Gas)
Explosive environment which exist continuously, usually and with a long period of time and which is
formed by a mixture of air with flammable material such as gas, vapor or droplets.
Zone1(Gas)
Explosive environment which sometimes exist under a normal operation and which is formed by a
mixture of air with flammable material such as gas, vapor or droplets.
Zone2(Gas)
Explosive environment which is impossible to exist under a normal operation or for only a short time
even if it exists and which is formed by a mixture of air with flammable material such as gas, vapor
or droplets.
Zone20(Dust)
Explosive environment which exist continuously, usually and with a long period of time and which is
formed by flammable dust cloud in the air.
Zone21(Dust)
Explosive environment which sometimes exist under a normal operation and which is formed by
flammable dust cloud in the air.
Zone22(Dust)
Explosive environment which is impossible to exist under a normal operation or for only a short time
even if it exists and which is formed by flammable dust cloud in the air.
Summary of Contents for ExP Series
Page 1: ...1 ...
Page 6: ...6 1 4 ATEX code description II 2 G c IIB T4 II 2 G Ex d IIB T4 Gb ...
Page 8: ...8 RC2 180 ExP A B RC2 200 ExP A ...
Page 9: ...9 RC2 200 ExP B RC2 230 ExP A B UNIT SI mm Imperial in ...
Page 10: ...10 RC2 260 ExP A B SI mm Imperial in UNIT RC2 300 ExP 320 ExP A ...
Page 11: ...11 RC2 300 ExP 320 ExP B RC2 310 ExP A B ...
Page 12: ...12 RC2 340 ExP 370 ExP A RC2 340 ExP 370 ExP B ...
Page 13: ...13 RC2 410 ExP A B RC2 470 ExP A ...
Page 14: ...14 RC2 470 ExP B RC2 510 ExP A B ...
Page 15: ...15 RC2 550 ExP A RC2 550 ExP B ...
Page 16: ...16 RC2 580 ExP A B RC2 620 ExP A B ...
Page 17: ...17 RC2 710 ExP A RC2 710 ExP B ...
Page 18: ...18 RC2 790 ExP A RC2 790 ExP B SI mm Imperial in UNIT ...
Page 19: ...19 RC2 830 ExP A RC2 830 ExP B ...