Chapter 6
Chapter 8 - 3
Power automatically turns off after turned on
Report to your local distributor
The distributor may have to replace the main
board. Report the symptoms to your local
distributor and wait for our instruction
Check the battery voltage
Multiscan requires the power of 8V or higher for
proper operation. Insufficient vehicle battery
voltage may result in prompt system turn off.
Check the vehicle battery voltage
It is normal. It is higher than 10 V
It is lower than 10 V
Use the other power source
Replace the vehicle battery with fresh new one.
Or use external vehicle battery for temporary
power supply.
It is normal. It is higher than 600mA
It is lower than 600mA
Use the other power source
Replace the vehicle battery with fresh new one.
Or use external vehicle battery for temporary
power supply.
Check the power Amperage
Multiscan requires the power of 600mA or more
for proper operation. Insufficient power amperage
may result in prompt system turn off.