Operation  

 

 

1

 

Setting the Clock 

2

Operating in Manual Mode 

This setting allows you to set the clock to local time. 
a) Press MENU until CLOCK LED indicator is lit and the digit indicator 

is flashing. Then press OK. 

b) When AM and PM begins to flash, press the UP or DOWN arrow 

button to select AM or PM and press OK. 

c) When the Hour begins to flash, press the UP or DOWN arrow to 

desired hour and  press OK. 

d) When the Minute begins to flash, press the

 

UP or DOWN arrow to 

desired Minute and press OK. 

e) The Clock setting is now complete. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

NOTE: To scroll through the clock settings more 
quickly, press and hold down the UP and DOWN 
arrows.

 

This setting allows you to immediately turn the lights on and turn them 
off when you no longer need them. 
a) Press MENU until MANUAL ON/OFF LED indicator is lit and then 

press OK. 

b) The MANUAL ON/OFF mode is now set to ON. Press the UP arrow 

button to turn on the lights. Press the DOWN arrow button to turn off 
the lights.  

 

3

 

Setting PHOTOCELL AUTO ON/OFF  

4

 

Setting PHOTOCELL ON / TIME OFF 

This setting allows the photocell to turn the lights on at dusk and off 
at dawn. 
a) Press MENU until the PHOTOCELL AUTO ON/OFF LED indicator is lit 

and then press OK. The PHOTOCELL  AUTO ON/OFF mode is now 
activated. The digit display shows the current time and the AM/PM 
LED indicator stays lit. 

b) The start delay time is 0.1 sec. 

±

 1 sec. ; The off delay time is 60 

sec. 

±

 10 sec. 

 

This setting allows the photocell to turn the lights on and you set the 

time they go off. 

a) Press MENU until the PHOTOCELL ON / TIME OFF LED indicator is lit 

and press OK. The display shows "OFF". 

b) When AM and PM begins to flash, press the UP or DOWN arrow 

button to select AM or PM and press OK. 

c) When the Hour begins to flash, press the UP or DOWN arrow to 

desired hour and press OK. 

d) When the Minute begins to flash, press the UP or DOWN arrow to 

desired Minute and press OK. 

e) The setting is now complete. The PHOTOCELL ON/ TIMER OFF LED  

indicator stays lit and the display shows the current time. The lights 
will automatically turn on at night and will turn off after a set time 
interval. 

 
 
 
 
 
 
 
 
  

Summary of Contents for SL-200-12A

Page 1: ...ce your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Item 1001 509 809 Model SL 200 12A USE AND CARE GUIDE TRANSFO...

Page 2: ...e experiencing problems contact a qualified electrician WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to...

Page 3: ...set up or used in any way not in accordance with the instructions supplied with the product This warranty shall not apply to a failure of the product as a result of an accident misuse abuse negligence...

Page 4: ...approved low voltage cable Failure to use at least 16 gauge minimum cable or install it as directed in these instructions may result in Risk of Fire or Electric Shock Using large cable will ensure ma...

Page 5: ...on the transformer Lay the transformer on a flat stable surface and insert the stripped end of one wire under the terminal clamping plate COM Then tighten the screw Repeat this procedure for clamping...

Page 6: ...e Be sure to leave minimum of 10 feet 3m of wire between the power pack and first fixture Turn the transformer on Attach your fixtures to the cable to using cable connectors as shown Place one connect...

Page 7: ...will have the transformer come on when it has become darker out The location position and orientation of the photocell can be adjusted until the transformer turns on at the desired light level If the...

Page 8: ...off the lights 3 Setting PHOTOCELL AUTO ON OFF 4 Setting PHOTOCELL ON TIME OFF This setting allows the photocell to turn the lights on at dusk and off at dawn a Press MENU until the PHOTOCELL AUTO ON...

Page 9: ...ing the external light signal the lights will turn on at dusk and off at dawn within 0 5 seconds NOTE When using the TEST function during daylight hours with the photocell installed on the transformer...

Page 10: ...chart 12 VOLT TAP Cable Length Total Fixture Wattage 0 50 feet 51 100 feet 101 150 feet 0 60 Watts 16 AWG 16 AWG 14 AWG 61 120 Watts 16 AWG 14 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not recommended 1...