background image

 5 

HAMPTONBAY.COM 

 

 

Please contact 1-855-HD-HAMPTON for further assistance. 

Installation  

 

 

 

1

 

Preparing the Cable 

2

Connecting the Cable to the 
Transformer 

Being careful when splitting NOT to expose the copper wire, remove 
the landscape wire insulation 1/2 in. from both wires and twist ends. 
Also, refer to strip length guide on the transformer.  

 
 
 
 
  

 

Lay the transformer on a flat, stable surface and insert the stripped 
end of one wire under the terminal clamping plate “COM”. Then 
tighten the screw. Repeat this procedure for clamping plate “12V” or 
“15V”. 
See cable selection chart for correct voltage tap. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

NOTE: Gently pull on the landscape wire to 
verify if the connection is strong.

 

 

NOTE: Verify that there are no loose cable strands.

WARNING: Risk of Fire 

 Make sure there is no wire insulation under the clamping 
plate and firmly tighten the terminal screws. 

 

Summary of Contents for SL-200-12A

Page 1: ...ce your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Item 1001 509 809 Model SL 200 12A USE AND CARE GUIDE TRANSFO...

Page 2: ...e experiencing problems contact a qualified electrician WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to...

Page 3: ...set up or used in any way not in accordance with the instructions supplied with the product This warranty shall not apply to a failure of the product as a result of an accident misuse abuse negligence...

Page 4: ...approved low voltage cable Failure to use at least 16 gauge minimum cable or install it as directed in these instructions may result in Risk of Fire or Electric Shock Using large cable will ensure ma...

Page 5: ...on the transformer Lay the transformer on a flat stable surface and insert the stripped end of one wire under the terminal clamping plate COM Then tighten the screw Repeat this procedure for clamping...

Page 6: ...e Be sure to leave minimum of 10 feet 3m of wire between the power pack and first fixture Turn the transformer on Attach your fixtures to the cable to using cable connectors as shown Place one connect...

Page 7: ...will have the transformer come on when it has become darker out The location position and orientation of the photocell can be adjusted until the transformer turns on at the desired light level If the...

Page 8: ...off the lights 3 Setting PHOTOCELL AUTO ON OFF 4 Setting PHOTOCELL ON TIME OFF This setting allows the photocell to turn the lights on at dusk and off at dawn a Press MENU until the PHOTOCELL AUTO ON...

Page 9: ...ing the external light signal the lights will turn on at dusk and off at dawn within 0 5 seconds NOTE When using the TEST function during daylight hours with the photocell installed on the transformer...

Page 10: ...chart 12 VOLT TAP Cable Length Total Fixture Wattage 0 50 feet 51 100 feet 101 150 feet 0 60 Watts 16 AWG 16 AWG 14 AWG 61 120 Watts 16 AWG 14 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not recommended 1...

Page 11: ...s problems missing parts Before returning to the store call HamptonBay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...