background image

RDB9144-WH/BN/ORB

 

Table of Contents

Table of Contents

2

Safety Information

2

Warranty

3

Operation

10

Care and Cleaning

11

Troubleshooting

11

Safety Information

PLEASE READ AND SAVE THESE INSTRUCTIONS.

.

1. To reduce the risk of electric shock, ensure electricity has been

 

turned off at the circuit breaker or fuse box before beginning.

2. All wiring must be in accordance with the National Electrical

 

Code, 

/

,  

ANSI NFPA 70 and local electrical codes. Electrical 

installation should be performed by a qualified licensed 

electrician

.

3. The outlet box and support structure must be securely mounted

 

and capable of reliably supporting a minimum of 35 pounds. Use
only UL Listed outlet boxes marked "FOR FAN

 

SUPPORT."

4. Do not operate the reversing switch while the fan blades are in

motion. The fan must be turned off and blades stopped before
reversing blade direction.

5. Avoid placing objects in the path of the blades. To avoid personal

injury or damage to the fan and other items, be cautious when
working around or cleaning the fan.

6. Do not use water or detergents when cleaning the fan or fan

blades

 

.

A dry dust cloth or lightly dampened cloth will be

suitable for most cleaning

.

7. After making electrical connections, spliced conductors should 

be turned upward and pushed carefully up into the outlet box.
The wire should be spread apart with the grounded conductor
and the equipment-grounding conductor on one side of the
outlet box. Splices after being made should be turned upward
and pushed carefully up into the outlet box.

8. Electrical diagrams are for reference only. Light kits that are not

packed with the fan must be UL Listed and marked suitable for
use with the model fan you are installing. Switches must be UL
General Use Switches. Refer to the instructions packaged with
the light kits and switches for proper assembly.

WARNING

Before servicing or cleaning unit, switch power

off at service panel, and lock service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning

.

WARNING

To reduce the risk of fire, electric shock or

personal injury, mount to an outlet box acceptable for fan 
support of 15.9 Kg (35 lbs) or less. Use mounting screws
provided with the outlet box. Most outlet boxes commonly
used for the support of lighting fixtures are not acceptable for
fan support and may need to be replaced. Consult a qualified

 

electrician if in doubt

.

WARNING

To  reduce the risk of personal injury, do not bend

the blade brackets when installing the brackets, balancing the
blades, or cleaning the fan. Do not insert foreign objects in
between rotating fan blades.

WARNING

To  reduce  the risk of fire or electric shock, do not

use this fan with any solid-state speed control device.

CAUTION

To reduce the risk of injury to person, the fan

must be mounted with a minimum of 7 feet clearance from the
trailing edge of the blades to the floor

.

2

RK7R

Specification

3

Pre-Installation

3

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

5

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tools Required

3

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hardware Included
Package Contents

3

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for RDB9144-WH

Page 1: ...USE AND CARE GUIDE MONTGOMERY 44 IN CEILING FAN An electronic copy of this user manual can also be obtained online at homedepot com Model RDB9144 WH BN ORB...

Page 2: ...Splices after being made should be turned upward and pushed carefully up into the outlet box 8 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL Listed...

Page 3: ...ersons shall render the warranty invalid There is no other express warranty The retailerhereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a...

Page 4: ...ted below A B C D E F G Part Description Quantity A Mounting plate 1 B Ceiling canopy 1 C Fan motor with switch housing 1 D Set of blade holders with blade holder screws pre installed E Set of blades...

Page 5: ...there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 3 available at your Retailer Figure 1 Figure 2 Figure 3 Outlet Box Outlet Box Outlet Box Pl...

Page 6: ...the center hole in the mounting plate as shown in Figure 6 Figure 6 Outlet Box REMEMBER to turn off the power Follow the steps below to hang Securely tighten the two mounting screws Carefully lift th...

Page 7: ...the neutral fan white wire to the white neutral household wire Connect the fan ground wires green on the mounting plate and the downrod assembly to the household ground wire After connecting the wire...

Page 8: ...e holder screws 1 2 Repeat these steps to install the remaining blade assemblies Figure 13 Attaching the fan blades Mount the blade holders D to the fan blades E using the square neck screws AA hex nu...

Page 9: ...ement Repeat for each blade Measurements should be within 1 8 in If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in s...

Page 10: ...n forward switch down or reverse switch up Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 17 This allows you to set your air conditioner on a higher setting witho...

Page 11: ...hoe polish There is no need to oil your fan The motor has permanently lubricated bearings Troubleshooting WARNING Make sure the power is off at the electrical panel box before you attempt any repairs...

Page 12: ...An electronic copy of this user manual can also be obtained online at homedepot com Retain this manual for future use...

Page 13: ...N m de modelo VENTILADOR DE TECHO MONTGOMERY DE 44 PULG RDB9144 WH BN ORB Puede obtener tambi n una copia electr nica de este manual del usuario en l nea en homedepot com GU A DE USO Y CUIDADO...

Page 14: ...o o limpiar la unidad desconecte la energ a en el panel de servicio y cierre el servicio desconectando los medios para evitar que la energ a se active accidentalmente Cuando los medios de desconexi n...

Page 15: ...ar la garant a No hay otra garant a expresa Por la presente el distribuidor renuncia a cualquier y todas las garant as incluyendo pero no limitadas a Garant as de comercializaci n o idoneidad para un...

Page 16: ...RDB9144 WH BN ORB I 4 Pieza Descripci n Cantidad A Placa de montaje 1 B Cubierta del techo 1 C Motor del ventilador con carcasa de interruptor 1 D Conjunto de soportes de las aspas con tornillos de s...

Page 17: ...colgar su ventilador donde ya hay una luminaria pero no una viga de techo puede necesitar un barra colgador como se muestra en la Figura 3 disponible en su tienda minorista el distribuidor Figura 1 F...

Page 18: ...asar los cables de alimentaci n de 120 voltios a trav s del hueco del refuerzo superior del motor se muestra en la Figura 6 RECUERDE desconectar el suministro de electricidad Para colgar el ventilador...

Page 19: ...s usado Conecte el cable neutro del ventilador blanco al cable neutro blanco de la vivienda Conecte los cables de conexi n a tierra del ventilador verde en la placa de montaje y la unidad de la vara c...

Page 20: ...a de la cubierta del techo Deslice las ranuras bayoneta en la cubierta del techo sobre los tornillos en cada extremo de la placa de montaje y aseg relas con los cuatro tornillos incluidos Figura 11 Fi...

Page 21: ...ada para medici n Repita para cada aspa Las medidas deben estar dentro de 1 8 pulg Si todav a se nota bamboleo en el aspa el intercambio de dos aspas adyacentes lado por lado puede redistribuir el pes...

Page 22: ...ba Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto de enfriamiento como se muestra en la Figura 17 Esto le permite ajustar su acondicionador de aire a un ajuste m s alto sin af...

Page 23: ...ne cojinetes lubricados permanentemente Soluci n de problemas ADVERTENCIA Aseg rese de que la energ a est desconectada en la caja del panel el ctrico antes de intentar cualquier reparaci n Consulte la...

Page 24: ...Puede obtener tambi n una copia electr nica de este manual del usuario en l nea en homedepot com Conserve este manual para uso futuro...