Hampton® H35U Direct Vent Freestanding Gas Stove
39
installation
Wiring Diagrams
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.
If any of the original wires as supplied with the
appliance must be replaced, it must be replaced
with CSA type SEW (200
o
C) or its equivalent.
This heater does not require a 120V A.C.
supply for operation. In case of a power failure,
the burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
WARNING: Electrical Grounding
Instructions
This appliance is equipped with a
three pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
Ground
Green
Neutral
Live
Black
ON
OFF
To Thermocouple IN
I H
O
L
F
F
O
N
O
O L
I
T
P
ON
OFF
Regency
White
(To THTP)
(To TH)
Gas In
DC
SPARKER
Cut here
White
Grey
Red
Remote
(OPTIONAL REMOTE)
Receiver
Remote
Red
Green
Green
Black
Black
Fan
Rotary Speed
Control
Fan Thermodisc
(normally open)
Summary of Contents for H35U-LP
Page 51: ...Hampton H35U Direct Vent Freestanding Gas Stove 51 notes...
Page 56: ...56 Hampton H35U Direct Vent Freestanding Gas Stove warranty...
Page 57: ...Hampton H35U Direct Vent Freestanding Gas Stove 57 notes...
Page 58: ...58 Hampton H35U Direct Vent Freestanding Gas Stove notes...
Page 59: ......