Hampton® H35U Direct Vent Freestanding Gas Stove

installation

**

**Note: Riser vent is only for use in above 

grade terminations. 

Diagram 2a

Diagram 3

shown in diagram 3. Cut and frame the 10 inch 
square hole in the exterior wall where the vent 
will be terminated. If the wall being penetrated 
is constructed of non-combustible material, i.e. 
masonry block or concrete, a 7" diameter hole 
is acceptable.

*As  specified  in  CAN/
CSA B149.1 Installation 
Code.  Local  codes  or 
regulations may require 
different clearances.

Diagram 2

Diagram 1: 

Hint: Apply 

silicone to 

female end.

Horizontal Installations - Rigid 
Vent System

1)

  Set  the  unit  in  its  desired  location.  Check  to 

determine  if  wall  studs  or  roof  rafters  are  in 
the way when the venting system is attached. 
If this is the case, you may want to adjust the 
location of the unit.

2)

  Direct Vent pipe and fittings are designed with 

special twist-lock connections to connect the 
venting system to the appliance flue outlet. A 
twist-lock appliance adaptor is installed on the 
unit at the factory. Assemble the desired com-
bination of pipe and elbows to the appliance 
adaptor with pipe seams oriented towards the 
wall or ceiling, as much out of view as possible. 
The final positioning of the pipe and 90

o

 elbow 

assembly is determined by the mounting orienta-
tion of the adaptor on the stove and twist-locked 
for a solid connection.

 

 

Below Grade Snorkel Installation

 

If  the  Snorkel  Termination  must  be  installed 
below grade, i.e. basement application, proper 
drainage  must  be  provided  to  prevent  water 
from entering the Snorkel Termination. Refer to 
Vent Manufacturer Installation instructions for 
details. Do not attempt to enclose the Snorkel 
within the wall, or any other type of enclosure.

3)

  With the pipe attached to the stove, slide the 

stove into its correct location, and mark the wall 
for a 10" x 10" (inside dimensions) square hole. 
The center of the square hole should line up 
with the center line of the horizontal pipe, as 

Note:
 a)

  Twist-lock  procedure:  Four  indentations, 

located on the female ends of pipes and fit-
tings, are designed to slide straight onto the 
male ends of adjacent pipes and fittings, by 
orienting the four pipe indentations so they 
match and slide in to the four entry slots on 
the male ends (Diagram 1). Push the pipe 
sections completely  together, then twist-
lock one section clockwise approximately 
one-quarter  turn,  until  the  two  sections 
are  fully  locked. The  female  locking  lugs 
will not be visible from the outside on the 
Black Pipe or fittings. They may be located 
by examining the inside of the female ends. 

 b)

  Horizontal runs of vent must be supported 

every three feet. Wall straps are available 
for this purpose.

 c)

 

Snorkel Terminations:

 

 

For  installations  requiring  a  vertical  rise 
on the exterior of the building, 14-inch and 
36-inch tall Snorkel Terminations and the 
Riser Vent  as shown in Diagrams 2 & 2a 
are available. Follow the same installation 
procedures as used for standard Horizontal 
Termination.  NEVER  install  the  snorkel 
upside down.

NOTE: For best results and optimum perfor-

mance with each approved venting sys-
tem, it is highly recommended to apply 
“Mill-Pac” sealant (supplied) to every 
inner pipe connection. Failure to do so 
may result in drafting or performance 
issues not covered under warranty. 
Silicone (red RTV) is optional.

Summary of Contents for H35U-LP

Page 1: ...ve the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installati...

Page 2: ...instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Paper Size 5 965 W x 5 71 H Color As shown in artwork DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTI...

Page 3: ...TURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 28 1 8 714mm 6 1 4 159mm 26 7 16 671mm 16 13 16 427mm 15 7 16 391mm 2...

Page 4: ...pton H35U Direct Vent Freestanding Gas Stove dimensions 28 1 8 714mm 6 1 4 159mm 26 7 16 671mm 16 13 16 427mm 15 7 16 391mm 25 5 16 643mm 27 1 2 699mm 16 1 4 412mm 22 13 16 580mm Unit Dimensions Rear...

Page 5: ...ion Precautions 14 Safety Precautions for the Installer 14 Vent Restrictor Position 14 Fan Installation 15 Exterior Vent Terminal Locations 16 4 x 6 5 8 Rigid Pipe Cross Reference Chart only 17 Rigid...

Page 6: ...que minimal Taille de l orifice Altitude Pression d alimentation minimale Pression manifold lev e Pression manifold basse D bit calorifique maximal D bit calorifique minimal Taille de l orifice Altitu...

Page 7: ...e unit converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration compl...

Page 8: ...Was the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if insta...

Page 9: ...in your building Leave the building immediately Immediately call your gas supplier from a neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de...

Page 10: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 11: ...on producthasbeentestedandlistedby ITS Testing Services as a Direct Vent Wall Furnace to ANSI Z21 88 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installat...

Page 12: ...actmeasurementsforclearances andfloorprotectionbeforeactuallyinstallingthis appliance Have a qualified building inspector review your plans before installation CLOTHING OR OTHER FLAMMABLE MATERIAL SHO...

Page 13: ...c DV Stove Horizontal Vent Kit d Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Con nection section Test the pilot Must be as per diagram in the Maintenance Instruction section If c...

Page 14: ...stion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room air up the chimney N...

Page 15: ...prong receptacle Do not cut or remove the grounding prong from this plug Removing the Fan 1 Unplug or disconnect power source to stove 3 Lift the back cover panel up a unit Take care note to pull o b...

Page 16: ...center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inl...

Page 17: ...Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 4...

Page 18: ...p 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946...

Page 19: ...AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent Pro are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product ha...

Page 20: ...nations Maximum one 90O elbow two 45o elbows equal one 90o elbow All approved caps listed on page 12 may be used Propane and Natural Gas Residential Manufactured and Mobile Home Installations The vent...

Page 21: ...permitted Venting Arrangements Straight Horizontal Termination The diagrams show all allowable combina tionsofstraighthorizontalterminationusing Rigid Pipe Restrictor position A Only a snorkel or FPI...

Page 22: ...ontal Please note minimum 1 foot between 90o elbows is required A 3 914 mm min 2 610 mm max B 4 1 2 m min 3 914 mm max C 5 1 5 m min 4 1 2 m max D 6 1 8 m min 5 1 5 m max E 7 2 1 m min 6 1 8 m max F 8...

Page 23: ...1 5 m max 5 1 5 m min E 6 1 8 m max 6 1 8 m min Lengths do not include elbow indicated Vent restrictor position A fully open Refer to the Vent Restrictor Posi tion section Option V H V V1 With these o...

Page 24: ...as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Straight Vertical Terminations Required Parts Part Description 946...

Page 25: ...ut withthe45o elbow willseatontoboththe startercollarandthe90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including ve...

Page 26: ...erature silicone and securing with 3 of the 8 x 1 2 black screws 15 Attach the pipe section to the 45o elbow by sealing with Mill Pac and or high temperature silicone and securing with 3 of the 8 x 1...

Page 27: ...he wall It is also important to note the important to note the wall thickness The wall thimble is suitable for 2 x 4 or 2 x 6 wall construc Warning Always maintain required clearances air spaces to ne...

Page 28: ...e SnorkelTermination Refer to Vent Manufacturer Installation instructions for details Do not attempt to enclose the Snorkel within the wall or any other type of enclosure 3 With the pipe attached to t...

Page 29: ...hing the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect the strips to the pipe Bend any remaining p...

Page 30: ...r mancewitheachapprovedventingsys tem it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not cover...

Page 31: ...ir intake is not covered under the ANSI Z21 88a 10007 CSA2 33a 10007testmethodsandtheresulting ITS WHIproductcertification ThecodeAuthor ityHavingJurisdictionmustbeconsultedprior to proceeding with th...

Page 32: ...dividual manual shut off valve during the testing Round Support RDS Square Support SQS If your home has a cathedral ceiling no attic space betweentheceilingandtheroof installthechimney and support as...

Page 33: ...ve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pres sure tap s...

Page 34: ...can be adjusted by moving the adjust ing wire up or down The wire is accessed through the bottom Open the air shutter for a blue flame or close for a yellower flame The burner aeration is factory set...

Page 35: ...the control panel door 3 Remove the logs embers and brick panels if used 4 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 6 Unscr...

Page 36: ...n wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 4 WARNING Do not overtighten the screw Recommended to grip the wrench by the short side 15 Verify that if the co...

Page 37: ...manual 3 Sprinkle the embers on the left and right sides of the firebox base A 02 43 D 02 46 G 02 48 C 02 44 B 02 56 F 02 47 E 02 45 Optional Brick Panel 1 Remove the cast top and glass front see Glas...

Page 38: ...re to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45...

Page 39: ...ver a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges WARNING Electrical Grounding Instructions T...

Page 40: ...the TH onthegasvalve Usetablebelowtodetermine the maximum wire length Note Preferable if the thermostat is installed on an interior wall Hampton offersanoptionalprogrammablethermo stat but any 250 750...

Page 41: ...from manufactur ing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning DONOTATTEMPTTOCLEANTHEGLASSWHILE...

Page 42: ...gas supplier from a neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob...

Page 43: ...contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTEDTOTHE HAZ ARDSOFHIGHSURFACETEMPERA TU...

Page 44: ...as shown in the diagram under Log Installation Note Improper positioning of logs may create carbon build up and will alter the unit s performance which is not covered under warranty Glass Replacement...

Page 45: ...y steps 13 19 10 Remove all 18 screws holding the burner tray assembly in place 12 To replace the burner tray assembly simply reverse these instructions Toremovevalvefromvalveassembly continue 13 Remo...

Page 46: ...ional Fan instructions above Servicing the Thermodisc To replace or service the fan thermodisc temperature switch use the following steps 1 Unplug or disconnect power source to stove 2 Remove two scre...

Page 47: ...he list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Opera...

Page 48: ...43 225 Cast Right Timberline Brown 743 227 Cast Right Seaside Sand 12 743 231 Cast Front Charcoal Grey 743 235 Cast Front Timberline Brown 13 743 271 Top Cast Grill Charcoal Grey 743 275 Top Cast Gril...

Page 49: ...N S 904 529 Allen Key 5 32 Long N S 910 940 Black Protective Cap Hi Low Control Knob N S 911 137 Pilot Hood Clip N S 910 941 4 m m Valve Screw With Red O Ring N S 932 012 3 8 Stainless Steel Flexible...

Page 50: ...an Kit Complete N S 740 901 Brick Panels Rustic Brown N S 740 902 Brick Panels Old Town Red N S 744 969 LP Conversion Kit N S 910 399 Fire genie Remote Control N S 910 407 Basic Wall Thermostat N S 91...

Page 51: ...Hampton H35U Direct Vent Freestanding Gas Stove 51 notes...

Page 52: ...ontrol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystal...

Page 53: ...rafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of r...

Page 54: ...the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authori...

Page 55: ...ow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product...

Page 56: ...56 Hampton H35U Direct Vent Freestanding Gas Stove warranty...

Page 57: ...Hampton H35U Direct Vent Freestanding Gas Stove 57 notes...

Page 58: ...58 Hampton H35U Direct Vent Freestanding Gas Stove notes...

Page 59: ......

Page 60: ..._____________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _________...

Reviews: