Hampton® H15-10 Direct Vent Freestanding Gas Stove
|
25
25
|
installation
Basic
Horizontal Kit
1
90
o
Elbow
1 Wall Thimble Cover
1 Horiz. Sq. Term. Cap
DURA-VENT TERMINATION KIT
Planning Your Dura-Vent
Installation
There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termination
and vertical termination. Confirm the maximum
horizontal run and maximum vertical rise from
the diagrams in the "Rigid Pipe Venting Sys-
tems" section.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired
for "vertical-to-horizontal" type installations.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fill air spaces with
insulation.
The minimum clearance requirements between
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check
the vent termination clearance requirements
from decks, windows, soffits, gas regulators, air
supply inlets and public walkways as specified
in the "Exterior Vent Terminal Locations" section and
in your local building codes.
To determine the length of vent pipe required for
vertical installations, measure the distance from the
unit flue outlet to the ceiling, the ceiling thickness,
the vertical rise in an attic or second storey, and al-
low for sufficient vertical height above the roof line.
For multi-storey applications, fire stops are required
at each floor level. If an offset is needed, additional
pipe, elbows and supports will be required.
Do not exceed the maximum number of elbows.
One 90
o
for horizontal terminations and two 45
o
for
vertical termination.
You will require the following components with your
new Direct Vent Freestanding Gas Stove. Please
review your product to make sure you have everything
you need. In the event that you are missing any part,
contact your dealer.
AstroCap
Part# 946-523/P
Alternate Horizontal
Termination Caps
Alternate
Horizontal
Riser Vent
Terminal
Part# 640-530/P
The FPI AstroCap
TM
is certified for installations using FPI venting
systems as well as Simpson Dura-Vent® and Direct Vent.
The FPI AstroCap
TM
is a proprietary trademark of FPI Fireplace Prod-
ucts International Ltd.
Dura-Vent® and Direct Vent are registered and/or proprietary trademarks
of Simpson Dura-Vent Co. Inc.