Hampton GC60-2 Cast Pellet Stove Technical Manual
35
Page 1: ...GC60 2 WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury propertydamage orlossoflife Refertothismanual Forassistanceor additional information consult an authorize...
Page 2: ...0 920 and 4 to 6 flue adaptor 4PVP X6 See instruction manual for further information FIRE EXTINGUISHER AND SMOKE DETECTION All home with a pellet burning stove should have at least one fire extinguish...
Page 3: ...r Through Wall Installation 12 Horizontal Exhaust Through Wall Installation 13 Recommended Through Wall With Vertical Rise and Horizontal Termination Installation 15 Through Concrete Wall With Vertica...
Page 4: ...d to clean to be safe OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also ensure all...
Page 5: ...struction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT TH...
Page 6: ...alled on a hard stable combustible surface D L unit doit tre install e avec protection de plancher devant et au bord de la porte ouvrant avec au moins 6 152 mm La base de pi destal peut tre adapt e la...
Page 7: ...back of the pellet stove there will be two flat head screws that hold the hopper lid shut Remove both screws Once both screws have been removed open the hopper lid The serial number will be on the und...
Page 8: ...ial Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg...
Page 9: ...ly onto carpet If it is to be installed on a carpeted area a solid surface metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for c...
Page 10: ...g Figure 4 GC60 2 Clearance to Combustibles Thermostat Installation 1 Install the wall thermostat millivolt rated thermostat recommended or a 12 24 Volt rated thermostat set to millivolts in a locatio...
Page 11: ...terior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plant...
Page 12: ...nd mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The i...
Page 13: ...ctrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is mandatory Secure outside air connections directly to fresh air intake pipe and...
Page 14: ...ith at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed on a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the stove E...
Page 15: ...cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations may require a T and 3 to 5 feet 91 to 15...
Page 16: ...thimble 4 90 Elbow Vertical section of 4 pipe Wall Thimble 4 45 Elbow with screen or Termination Cap Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet s...
Page 17: ...nstallations section and then finish it by performing the following refer to Figure 15 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that y...
Page 18: ...s installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward from tee When you re...
Page 19: ...ist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 17 Hearth Mount Side View Figure 18 Hearth Mount Over View 1 Lock...
Page 20: ...102 mm to 6 152 mm Flue Adaptor 4PVP X6 See separate instruction manual for complete details Note Part 6DVL ADT Simpson Duravent DVL adaptor would also be required to connect the 4 102 mm 6 152 mm inc...
Page 21: ...e Functions can be used to compensate for varying fuel qualities Refer to the Owners Manual for circuit board operation If after long periods of burning the fire builds up or there is a build up of cl...
Page 22: ...g unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still does not start contact y...
Page 23: ...e Exhaust motor will not function normally and 5 Unit is on but auger does not turn at all for more suggestions Severe negative pressure in area where unit is installed Check the operation by opening...
Page 24: ...n make sure the thermostat is calling for heat Call your local dealer for service 11 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn pot liner the fire is go...
Page 25: ...e White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black White Green Ground 120V G...
Page 26: ...LLERS C W NUT GC60 031 not shown 2 AMP SMALL FUSE GC60 032 not shown 4 AMP SMALL FUSE IGNITOR GC60 033 not shown ADJ AUGER FEED COVER KIT N C PRE NOV 2010 GC60 034 not shown COMBUSTION BLOWER MOUNTING...
Page 27: ...C60 043 27 FIREBOX LOWER GC60 045 31 GC60 CONTROL PANEL WITH DECAL GC60 055 32 DAUGHTER BOARD GC60 022 33 MOTHER BOARD GC60 023 39 ASH PAN GC60 046 40 GLASS GC60 024 42 DOOR COMPLETE GC60 026 43 AUGER...
Page 28: ...Parts Diagram Components 26 22 48 19 54 1 52 55 2 53 23 25 10 44 32 33 11 24 4 9 6 3 12 21 20 40 50 31 39 42 47 15 8 7 49 56 43 51 5 14 16 27 46 17 45 18 Hampton GC60 2 Cast Pellet Stove Technical Man...
Page 29: ...60 CAST SIDE LEFT CHARCOAL GC60 241 62 GC60 CAST SIDE RIGHT CHARCOAL GC60 251 63 GC60 CAST LEG LIP LEFT CHARCOAL GC60 261 64 GC60 CAST LEG LIP RIGHT CHARCOAL GC60 271 65 GC60 CAST ASH DOOR CHARCOAL GC...
Page 30: ...acture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s op...
Page 31: ...cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados...
Page 32: ...r local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain...
Page 33: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Prod...
Page 34: ...Hampton GC60 2 Cast Pellet Stove Technical Manual 34 WARRANTY...
Page 35: ...Hampton GC60 2 Cast Pellet Stove Technical Manual 35...
Page 36: ...the following information Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________...