background image

 2 
 

Table of Contents 

Table of Contents .......................................................... 2

 

Safety Information ......................................................... 2

 

Warranty ......................................................................... 3

 

Pre-installation .............................................................. 3

 

Planning Installation ................................................................3

 

Installation Options ..................................................................4

 

Tools required ..........................................................................4

 

Materials required ....................................................................4

 

Hardware Included ...................................................................5

 

Package Contents ....................................................................5

 

Installation ..................................................................... 6

 

Care and Cleaning ...................................................... 10

 

Specifications ..............................................................  11

 

BPT18-34ALE-2 ......................................................................11

 

BPT18-54AL-1 ........................................................................11

 

Dimensions (BPT18-54AL-1 & BPT18-34ALE-2) ....................11

 

Service Parts ............................................................... 12

 

BPT18-34ALE-2 Serviceable Parts .........................................12

 

BPT18-54AL-1 Serviceable Parts ...........................................13

 

 

Safety Information 

 

1.

 

This ventilation fan is approved for use over a bathtub or 
shower when installed in a GFCI protected circuit. Do not 
use unapproved fans over a bathtub or shower that does not 
include a GFCI protected circuit. 

2.

 

Installation work must be carried out by a qualified person(s) 
in accordance with all local and safety codes including the 
rules for fire-rated construction.  

3.

 

To reduce the risk of fire, always vent fans to the exterior 
and in compliance with local codes. Do not vent exhaust air 
into spaces within walls, ceilings, attics, crawl spaces, or 
garages. 

4.

 

Install ductwork in a straight line with minimal bends. 

5.

 

Use 120 V, 60 Hz for the electrical supply and properly 
ground the unit. Follow all local safety and electrical codes.  

6.

 

Do not use this fan with any solid state control device; such 
as a dimmer switch. Solid-state controls may cause 
harmonic distortion, which can cause a motor humming 
noise. 

7.

 

To reduce the risk of fire, electric shock or injury to persons, 
observe the following: 

 

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer. 

 

Before servicing or cleaning the unit, switch the power 
off at the service panel and lock the service 
disconnecting means to prevent power from being 
switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten 
a prominent warning device, such as a tag, to the 
service panel. 

8.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent back drafting. Follow the 

heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for 
Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities. 

WARNING: 

Not suitable for use as a range hood or in 

areas where hazardous or explosive vapors are present.

 

 

WARNING: 

FOR USE IN NON FIRE-RELATED 

INSTALLATIONS ONLY.

 

 

WARNING: 

FOR USE IN ONE-AND-TWO FAMILY 

DWELLINGS ONLY

 

 

WARNING: 

To reduce the risk of fire or electric shock, do 

not use this fan with any solid-state speed control device.

 

 

CAUTION: 

Do not install in locations where the air 

temperature will exceed 104°F (40°C).

 

 

CAUTION: 

For general ventilating use only. Do not use to 

exhaust hazardous or explosive materials and vapors.

 

 

IMPORTANT: 

Exercise care to not damage existing 

wiring when cutting or drilling into walls or ceilings.

 

 

IMPORTANT: 

You may want to consult with a 

professional electrician regarding the wiring of your 
ventilation fan.

 

NOTE: 

Make sure the duct work size is a minimum of the 

discharge. Do not reduce. Reducing the duct size can 
increase fan noise.

 

NOTE: 

Proper installation of insulation around and over 

fan body to minimize building heat loss and gain.

 

 
 

Summary of Contents for BPT18-34ALE-2

Page 1: ...your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Item 316 622 Model BPT18 34ALE 2 Item 316 183 Model BPT18 54AL 1...

Page 2: ...ions contact the manufacturer Before servicing or cleaning the unit switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidenta...

Page 3: ...replacement as well as incidental and consequential damages connected with the above are excluded Any damage to this product as a result of neglect misuse accident improper installation or use other t...

Page 4: ...ns possible for this ventilation fan Not all configurations are shown If your installation requires a variation other than those shown consult with a licensed contractor to determine the best installa...

Page 5: ...iption Quantity AA Quick connect 7 BB Long wood screw M4x30 8 CC Short screw M4x10 4 DD Short screw M4x12 2 EE Short screw M4x8 1 PACKAGE CONTENTS Part Description Part Description A Fan body E Suspen...

Page 6: ...I F Proceed to step 4 Use the screw EE to secure the suspension bracket D to the fan body A Use the screws DD to secure the suspension brackets E and F to the fan body A Suspension brackets I D and II...

Page 7: ...r bars to the opposite ceiling joist Secure the suspension brackets D E and F to the joist using long wood screws BB Ensure the main body is level and square to the joists Tighten all screws CAUTION D...

Page 8: ...STRAND WARNING Make sure that the main power is off WARNING Failure to wire this product correctly could result in electrical shock fire hazards or damage to the product Consult a licensed electricia...

Page 9: ...TON for further assistance Installation continued 8 Connecting the grill 9 Mounting the grill Plug the connector into the receptacle Mount the grill B using the screws CC 10Installing the bulbs Instal...

Page 10: ...ve dust and dirt from the fan housing with a vacuum cleaner Dampen a cloth with dish detergent wipe the fan housing and dry with a cloth Replace the grill To reduce the risk of fire always vent fans t...

Page 11: ...6 42 Kg BPT18 54AL 1 Model No BPT18 54AL 1 Air direction 140 cfm Voltage 120 V Hertz 60 HZ Duct diameter 6 in 15 cm Noise 1 1 Sone Power consumption Watts 41 W Speed 811 rpm Air deliver at 0 1 WG 140...

Page 12: ...30 8 BGBPT18010 Grill lens 1 UC40400802 Short screws M4x8 1 HTBPT1801 GU24 13W CFL bulb 2 ABPTAL5603 Grill lamp box and sockets and spring clip 1 HTSQL0003 4W incandescent night light 1 ABPTAL3404 Com...

Page 13: ...racket 1 UB40403001 Long wood screws M4x30 8 BGBPT18010 Grill lens 1 UC40400802 Short screws M4x8 1 HTBPT1801 GU24 13W CFL bulb 2 ABPTAL5603 Grill lamp box and sockets and spring clip 1 HTSQL0003 4W i...

Page 14: ...stions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use 20140808 B...

Page 15: ...as para el hogar racias por elegir Hampton Bay usted Art culo n m 316 622 Modelo n m BPT18 34ALE 2 Art culo n m 316 183 Modelo n m BPT18 54 1 GU A DE USO Y MANTENIMIENTO VENTILADOR Preguntas problemas...

Page 16: ...la unidad desde el panel el ctrico antes de limpiarla o darle mantenimiento y cierra los medios de desconexi n del panel para evitar que la electricidad sea encendida accidentalmente Cuando los medios...

Page 17: ...vados Todo da o provocado a este producto como resultado de negligencia uso indebido accidente instalaci n inapropiada o cualquier otro uso distinto al prop sito ANULAR LA PRESENTE GARANT A Comun cate...

Page 18: ...aciones Si tu instalaci n necesita una variaci n distinta a las que se muestran consulta a un contratista para determinar la mejor instalaci n para tu proyecto Si est s reemplazando un ventilador ya e...

Page 19: ...ONTENIDO DEL PAQUETE www hamptonbay com Para obtener asistencia llama al 1 855 HD HAMPTON DD Tornillo 2 BB CC DD EE AA Pieza Descripci n A Cuerpo del ventilador B Rejilla C Lente de rejilla D Soporte...

Page 20: ...ermitir un posicionamiento preciso del cuerpo principal entre las vigas Usa el tornillo EE para asegura los sopportes de suspensi n D en el cuerpo del ventilador A Usa el tornillo DD para asegura los...

Page 21: ...la viga mediante los tornillos de madera largos BB Aseg rate de que el cuerpo principal est a nivel y a escuadra de las vigas Ajusta todos los tornillos PRECAUCI N No montes el ventilador al ras de la...

Page 22: ...aras La clasificaci n de inflamabilidad de los cables debe ser UL94 V2 La clasificaci n aceptable incluye S lido AWG 12 20 Trenzado AWG 12 16 19 TRENZADO AWG 18 7 TRENZADO Soldado con esta o AWG 14 18...

Page 23: ...C mo instalar la rejilla Enchufa el conector al recept culo Monta la rejilla B con los tornillos CC 10 C mo instalar las bombillas Instala la bombilla Sujeta la lente de la rejilla C C www hamptonbay...

Page 24: ...sa del ventilador con una aspiradora Humedece el pa o con detergente lavaplatos limpia la carcasa del ventilador y seca con un pa o Vuelve a colocar la rejilla Para disminuir el riesgo de incendio los...

Page 25: ...60 HZ Di metro del ducto 6 plg 15 cm Ruido 1 1 Sone Consumo de energ a Vatios 41 W Velocidad 811 rpm Emisi n del aire a 0 1 WG 140 cfm Peso 14 12 lb 6 42 kg DIMENSIONES BPT18 54AL 1 Y BPT18 34ALE 2 A...

Page 26: ...sorte 1 ABPTAL3404 Ventilador ensamblado y carcasa completos 1 UC40401201 2 UC40400802 UB40403001 HM0000004 HTSQL0003 HTBPT1801 UC40401002 UC40401201 N mero de pieza Descripci n Cantidad ABPTAL05604 S...

Page 27: ...or ensamblado y carcasa completos 1 UC40401201 2 UC40400802 UB40403001 HM0000004 HTSQL0003 HTBPT1801 UC40401002 UC40401201 N mero de pieza Descripci n Cantidad ABPTAL05604 Soporte de suspensi n comple...

Page 28: ...ltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de 8 a m a 6 p m Hora Est ndar del Este de Lunes a Viernes Conserva este manual para referencias futuras 20140808 B 1...

Page 29: ...voir notre gamme erci d avoir choisi Hampton Bay Article n 316 622 Mod le n BPT18 34ALE 2 Article n 315 888 Mod le n n BPT18 54AL 1 GUIDE D UTILISATION ET D ENTRETIEN VENTILATEUR D A RATION Questions...

Page 30: ...e nettoyer ou d assurer l entretien de l unit coupez le courant lectrique au tableau de distribution et verrouillez le dispositif de sectionnement du service pour emp cher le Si le dispositif de secti...

Page 31: ...r sulte de la n gligence d un mauvais usage d un accident d une installation incorrecte ou d un usage autre que celui pour lequel il a t con u ANNULERA CETTE GARANTIE Communiquez avec l quipe du servi...

Page 32: ...tilateur d a ration Toutes les configurations ne sont pas illustr es Si votre installation n cessite une variante des configurations illustr es consultez un entrepreneur accr dit pour d terminer la me...

Page 33: ...llerie illustr e la grandeur nature Veuillez composer le 1 855 HD HAMPTON pour une assistance suppl mentaire BB CC DD EE AA Pi ce Description A Corps du ventilateur B Grille C Diffuseur D Support de s...

Page 34: ...ins rez les supports de suspension I D II E et III F Passez l tape 4 REMARQUE Des barres de suspension coulissantes sont fournies pour assurer un positionnement pr cis du corps principal entre les sol...

Page 35: ...l aide de vis bois longues BB V rifiez que le corps principal est de niveau et d querre par rapport aux solives Serrez toutes les vis ATTENTION Ne montez pas le ventilateur tout contre la solive La br...

Page 36: ...it nominale des fils doit tre conforme la norme UL94 V2 La gamme de fils acceptables comprend Massif calibre 12 20 AWG Toronn calibre 12 16 AWG 19 BRINS 180 AWG 7 BRINS Recouvert d tain 14 18 AWG 19 B...

Page 37: ...ge de la grille Branchez le connecteur dans la prise Montez la grille B l aide des vis CC 10 Installation des ampoules Installez l ampoule Attachez le diffuseur C C www hamptonbay com Veuillez compose...

Page 38: ...ur r duire les risques d incendie vacuez toujours l air des ventilateurs vers l ext rieur et conform ment aux codes locaux N vacuez pas l air de sortie dans les espaces interstitiels entre les murs le...

Page 39: ...60 Hz Diam tre du conduit 15 24 cm 6 po Bruit 1 1 Sone Consommation lectrique watts 41 W Rapidit 811 tr min D bit de l air fourni 0 1 po WG 140 pieds cubes par minute Poids 6 42 kg 14 12 lb DIMENSION...

Page 40: ...de 4 W 1 Pi ce n Description Quantit HM0000004 Connecteurs rapides 7 UB40403001 Vis bois longues 8 UC40400802 Vis courtes 1 ABPTAL5603 Grille bo tier et douilles de la lampe et pince ressort 1 ABPTAL3...

Page 41: ...004 Connecteurs rapides 7 UB40403001 Vis bois longues 8 UC40400802 Vis courtes 1 ABPTAL5603 Grille bo tier et douilles de la lampe et pince ressort 1 ABPTAL5601 Ventilateur compl tement assembl et bo...

Page 42: ...nquantes Avant de retourner au magasin veuillez communiquer avec le service la client le Hampton Bay entre 8 h et 18 h HNE du lundi au vendredi Conservez ce guide pour un usage ult rieur 20140808 B 1...

Reviews: