4
1.
The track section and floating live end connector must be assembled so that polarity between
conductors is maintained. NOTE: The floating live-end connector has a tab on one side of the track
has indentation which runs the length of the track channel (Refer to Fig.2). Align the floating
live-end connector tab with the track indentation and insert the floating live-end connector into the
track channel so that the base of connector fits flush against the track twist connector clockwise 1/4
(one quarter) turn so that the connector fits snugly against the track.
CATUTION:
When the floating live-end connector is twisted into position make certain that the two
copper tabs at the base of the connector align with the two copper bars inside the track, this is necessary
to maintain polarity.
2.
The floating live-end connector should be positioned along the track so that it will align with the
outlet box after track is installed. The plastic canopy must enclose the floating live-end connector
and cover the outlet box. The plastic canopy should not cover the track mounting attachment holes, it
should attach to the mounting plating with the 2 screws after Electrical connections are made.
STEP 2:
ATTACH MOUNTING PLATE TO TRACK
Place the mounting plate on the back side of the track section so that the set screws on plate fit over the
ridges on both sides of the track. This will insure grounding continuity. Center the plate which previously
installed floating live-end connector and tighten the set screws on both side of the track. Pass wires from
the floating live-end connector through the hole in the mounting plate into ceiling outlet box. (See Fig.3)
Fig. 2 Fig. 3
STEP 3:
ELECTRICAL CONNECTORS
1.
When removing the supply wires from the ceiling outlet box, the white supply and black supply wire
should be on one side of the track and green ground wire should be on the other.
2.
Connector he white wire from the supply circuit to the white from the floating live-end connector.
Connect the black wire from the supply circuit to the black wire from the floating live-end connector.
Connect the green ground wire from the supply circuit to the green conductor of the floating live-end
connector. Secure splices with UL Listed wire connection suitable for the size, type and number of
conductors. (See Fig. 4)