Installation (continued)

 

3

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

DD

Outlet Box

Installing the mounting bracket

4

EE

B

Secure the mounting plate (B) to the outlet box with machine 
screws (EE).

Installing the track to the ceiling

5

F

AA

Place the linear track section (F) in the desired location on the mounting plate (B) between the two track mounting screws (A). 
Mark the location of the track section (F) on the ceiling with a pencil (not included) through the mounting holes in the bottom of the  

 track section (F).  

Attach the track section (F) to the desired location on the ceiling in one of the following ways:

Drill a 5/8 in. hole at each mark on the ceiling. 
Insert toggle bolts (AA) through the track section (F), and 
thread 1/2 in. toggle onto bolts.  

     

Place the track section (F) against the ceiling, and insert the

toggle bolts (AA) into the holes until the springs open.   

Tighten the bolts (AA).  

5a

Connecting the wires

NOTE: 

 Toggle bolts (AA) should be used for standard installation into drywall, drop ceiling, or suspended ceiling 

applications. Anchors (CC) are used for masonry installations ONLY.

 

Toggle bolt installation


Connect the wires (white wires from connector to the white 
wires from the supply circuit, black wires from the connector 

to the black wires from the supply circuit, and the green 
ground wire from the connector to the ground wire of the 
supply circuit) using the wire connectors (DD). 
Wrap electrical tape (not included) around wire connectors 
(DD) and make sure they are secure. 

Push all excess wire and wire connectors (DD) back into the 

outlet box (not included).

Align the holes in the mounting plate (B) with the holes in the 
outlet box.  

Summary of Contents for 1004612881

Page 1: ...01WH 3 DC11001SBA 3 DC5150WH F Item 1004612899 805109 1004612881 805089 1004612902 805149 1004612893 805129 1004613000 805319 1004612993 805049 1004612904 805029 1004613002 805069 We appreciate the tr...

Page 2: ...aterial Tools Required NOTE All electrical connections must be in accordance with local codes and the National Electrical Code If you are unfamiliar with methods of installing electrical wiring secure...

Page 3: ...during shipping Keep your receipt and these instructions for proof of purchase Hacksaw NOTE Hardware not shown to actual size HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance fiv...

Page 4: ...unting plate B Mounting plate Twist lock connector preassembled to mounting plate B Canopy preassembled to mounting plate B Canopy screw preassembled to canopy D Track section Track head Connector s l...

Page 5: ...into the track leaving approx in space between the end of the track and the insulator copper bus bar assembly length of track that is 4 ft or less in length has one mounting opening spaced a maximum...

Page 6: ...olts Place the track section F against the ceiling and insert the toggle bolts AA into the holes until the springs open Tighten the bolts AA 5a Connecting the wires NOTE Toggle bolts AA should be used...

Page 7: ...with the two copper strips inside the track section F This is necessary to maintain polarity Installing the track head to the track 8 NOTE The ground side of the track head G connector is the side wi...

Page 8: ...will not illuminate Use a dry or slightly dampened clean cloth use clean water never use a solvent to wipe the interior and exterior surfaces of the Troubleshooting The power is off Check the wiring y...

Page 9: ...this manual for future use 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to store call Hampton Bay Customer Service 7 a m 6 p m EST Monday Friday 9 a m 6 p m EST Sa...

Page 10: ...ogar Gracias por elegir Hampton Bay 1 855 HD HAMPTON Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al servicio al cliente de Hampton Bay de lunes a viernes de 7 a m a 6 p...

Page 11: ...en un lugar h medo las cortinas y otros materiales combustibles n que no de la conformidad con el reglamento podr a anular la autorizaci n del usuario de hacer funcionar este aparato Reoriente o reub...

Page 12: ...defectos en materiales y mano de obra por un periodo de cinco a os a partir de la fecha de su compra Si durante este lapso el producto resulta defectuoso en cuanto a material omano de obra deber devol...

Page 13: ...stro de Electricidad preensamblado de placa de montaje B Cubierta preensamblado de placa de montaje B Tornillos de la Cubierta preensamblado de la cubierta D Secci n del carril Cabezal del carril Leng...

Page 14: ...riel Las aberturas adicionales cada 4 pies 1 22 m a lo largo de la secci n del riel se deben agregar seg n sea necesario Desliza las barras de distribuci n de cobre y los aislantes para que queden al...

Page 15: ...entes maneras enrosque tapas de pulg sobre los tornillos Coloque la secci n del carril F contra al techo e inserte los luego apriete los tornillos AA 5a Conectar los cables NOTA del techo Las anclas d...

Page 16: ...neal F Esto es necesario para mantenerla polaridad Instalar el jefe de riel hasta el riel 8NOTA El lado de puesta a tierra del conector del cabezal del carril G es el lado con las dos leng etas de met...

Page 17: ...oblemas del cableado Prueba o reemplaza el interruptor Jale hacia abajo la leng eta de bloqueo del conector H del cabezal del carril y gire hasta que el cabezal del carril G se libere Para retirar el...

Page 18: ...de regresar a la tienda llama al servicio al cliente de Hampton Bay de lunes a viernes de Conserva este manual para uso en el futuro VAHD9557 3 2 v 1 2019 10 7 a m a 6 p m hora est ndar del Este y s...

Reviews: