background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 13

Care and Cleaning ............................................................. 14

Troubleshooting ................................................................. 14

1. 

To reduce the risk of electric shock, ensure the electricity has been 
turned off at the circuit breaker or fuse box before you begin.

2. 

All wiring must be in accordance with the National Electrical Code 
ANSI/NFPA 70 and local electrical codes. Electrical installation should 
be performed by a qualified licensed electrician. 

3. 

The outlet box and support structure must be securely mounted and 
capable of reliably supporting a minimum of 35 lbs. (15.9 kg). Use 
only UL-listed outlet boxes marked “Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less.”

4. 

The fan must be mounted with a minimum of 7 ft (2.1 m) of 
clearance from the trailing edge of the blades to the floor.

5. 

Do not place objects in the path of the blades.

6. 

To avoid personal injury or damage to the fan and other items, use 
caution when working around or cleaning the fan.

7. 

After making electrical connections, spliced conductors should be 
turned upward and pushed carefully up into the outlet box. The 
wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on one side of the outlet box.

8. 

All set screws must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do 

not insert objects in the path of the blades.

WARNING:

 To reduce the risk of fire or electric

shock, do not use this fan with any solid-state speed

control device.

WARNING:

 Electrical diagrams are for reference 

only. If you are using a light kit, refer to the light kit

instructions manual to make the electrical

connections. Optional use of any light kit shall be

UL-listed and marked suitable for use with this fan.

WARNING:

 To avoid possible electrical shock, turn 

the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

WARNING:

 To reduce the risk of fire, electric shock 

or personal injury, mount to outlet box marked 
“Acceptable for fan support of 35 lbs. (15.9 kg) or 

less”, and use screws provided with the outlet box.

READ AND SAVE THESE INSTRUCTIONS.

WARNING:

 To reduce the risk of fire or electric 

shock, this fan should only be used with fan speed 

control part no. AP-8RDL, manufactured by Dawnsun 

Electronic Co., LTD.

CAUTION:

 Do NOT use this fan with a dimmer switch 

or wall control. Using a dimmer switch or wall control 

will damage the fan.

CAUTION:

 Changes or modifications not expressly 

approved by the party responsible for compliance 

could void the user’s authority to operate the 

equipment.

WARNING:

 To reduce the risk of electric shock, this 

fan must be installed with an isolating wall switch.

Summary of Contents for 1004 773 032

Page 1: ...ough the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay To view an instructional video on how to install this product 1 Go to www homedepot com and enter the item or model number found in the top right corner of t...

Page 2: ...ets also referred to as flanges during assembly or after installation Do not insert objects in the path of the blades WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device WARNING Electrical diagrams are for reference only If you are using a light kit refer to the light kit instructions manual to make the electrical connections Optional ...

Page 3: ...f removing and reinstalling the product are your responsibility Damage to any part such as by accident misuse improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest usef...

Page 4: ...4 Part Description Quantity AA Plastic wire connecting nuts 3 BB Hanger pin 1 CC Locking pin 1 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA BB CC ...

Page 5: ...llar cover 1 E Fan motor assembly 1 F Blade 5 Part Description Quantity G Light kit assembly 1 I Receiver 1 J Remote control 1 K Extension lead wire 1 L Battery 1 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation continued PACKAGE CONTENTS I J K G E F A B C D...

Page 6: ...et box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs 15 9 kg Use only UL listed outlet boxes marked Acceptable for fan support of 35 lbs 15 9 kg or less Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy touches the downrod then remove the decorative canopy bottom cover and ...

Page 7: ... E Carefully insert the hanger pin BB through the holes in the collar and ball downrod assembly B Be careful not to jam the hanger pin BB against the wiring inside the ball downrod assembly B Insert the locking pin CC through the hole near the end of the hanger pin BB until it snaps into its locked position Re tighten the setscrews JJ on the collar on top of the fan motor assembly E CAUTION To ens...

Page 8: ...tlet box as shown Securely tighten the two mounting screws TT Carefully lift the fan motor assembly E up to the slide on mounting bracket A Insert the ball portion of the ball downrod assembly into the socket of the slide on mounting bracket A Turn the ball downrod B assembly clockwise until it is seated with the tab of the slide on mounting bracket A aligned with the slot in the ball 1 2 WARNING ...

Page 9: ...place as this will damage the hand unit Dispose of used battery properly and keep the battery out of the reach of children 4 Installing the receiver Position the house supply wires AAA to one side of the slide on mounting bracket A position the fan wires BBB to the opposite side Insert the narrow end of the receiver I as shown flat side towards the ceiling into the slide on mounting bracket until ...

Page 10: ...cting nut AA Connect the receiver I white wire to the household white wire neutral using a wire connecting nut AA Secure each wire connecting nut using electrical tape WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician Wiring the fan to the...

Page 11: ... clockwise to lock in place Assembly Hanging the Fan continued 7 B C D E HH FF A II I Assembly Attaching the Fan Blade Attaching the blade to the motor 1 Attach a blade F to the fan motor housing E by inserting the blade F into the slot in the side of the fan motor housing E until it stops The locking clip LL will click when the blade is correctly installed Ensure the blade is snapped into locking...

Page 12: ...motor assembly E by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch cup and connect the safety cable SS from the light kit assembly G to the hook from motor assembly E Push the light kit assembly G up to the motor assembly E by aligning the magnet part of the motor assembly E till it is secure E G SS Hook ...

Page 13: ...remote control to operate the speed and lights of your new ceiling fan Speed setting for warm or cool weather depends on factors such as the room size ceiling height number of fans and so on The fan is shipped from the factory with the reversing switch YY positioned to circulate air downward If airflow is desired in the opposite direction turn your fan off and wait for the blades to stop turning t...

Page 14: ...bove the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same point on each blade to the ceiling Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes If the fan continues to wobble please contact Customer Service ...

Page 15: ...ference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly approved by the grantee of ...

Reviews: