background image

 13 HAMPTONBAY.COM
 

 

Please contact 1-855-HD-HAMPTON for further assistance.

 

The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

 

Certain materials or items, when stored under the heater, will be subjected to radiant heat and could be seriously damaged.

 

Inspect the visible portion of the hose before each use of the appliance. The hose inside cylinder pole housing should be checked 
annually and a leak test should be performed when re-assembled.

 

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing 
ignition.

 

Young children should be carefully supervised when they are in the area of the heater.

 

Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.

 

Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.

 

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least 
annually by a qualified service person.

 

More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air 
passageways of the heater be kept clean.

 

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

 

Do not obstruct the flow of combustion and ventilation air.

 

Keep the ventilation openings of the cylinder enclosure free and clear from debris.

 

The LP-gas supply cylinder to be used must be: a. Constructed and marked in accordance with the specifications for LP-gas 
cylinders of the U.S. Department of Transportation (DOT); or the Standard for cylinders, Spheres and Tubes for Transportation of 
Dangerous Goods and Commission, CAN/CSA-B339, as applicable; b. Provided with a listed overfilling prevention device; and c. 
Provided with a cylinder connection device compatible with the connection for the appliance. d. 20LB (9kg) cylinder. LPG capacity 
4.7 gallons (17.8 litres) Cylinder Dimensions: Height 17.75 inches (451mm) and width 12.25 inches (311mm) e. The LP - gas cylinder 
used must include a collar to protect the cylinder valve.

 

A cylinder must be stored outdoors in a well-ventilated area out of reach of children. A disconnected cylinder must have dust caps 
tightly installed and must not be stored in a building, garage or any enclosed area. The pressure regulator and hose supplied must 
be used and any replacement pressure regulator or hose must be those as specified by the manufacturer.

 

Do not store spare LP-gas cylinder under or near this appliance.

 

Never fill the cylinder beyond 80% full; and for appliances designed to use a CGA No. 791.

 

Connection: Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on 
the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

POSITIONING INSTRUCTIONS

 

This appliance is for OUTDOOR USE ONLY and should be placed in a well ventilated area.

 

A well ventilated area must have a minimum of 30% of its surface area open. (Surface area is defined as the total surface of the 
walls surface.)

 

The sides of the appliance should NEVER be closer than 40 inches (1m) from any combustible surface.

 

Keep this appliance away from any flammable materials!

40 in. (1M)

40 in. (1M)

Operation

Summary of Contents for 1002693243

Page 1: ...s online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay USE AND CARE GUIDE 48 000 COMMERCIAL GRADE HEAT FOCUSING PATIO HEATER Questions p...

Page 2: ...damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING NEVER use indoors in an enclosed area or below ground level WARNING...

Page 3: ...atio heaters WARNING Ensure the heater is at a safe distance from glass and PVC doors and windows to stop damage from any heat build up WARNING Read the warnings and use instructions before operation...

Page 4: ...r s receipt WHAT IS NOT COVERED Defects or damage caused by the use of other genuine parts are not covered by this warranty This warranty is valid for the original customer only and excludes product d...

Page 5: ...CLUDED NOTE Hardware not shown to actual size Part Description Quantity AA 1 4 in dome head bolt 32 BB 1 4 in nut 44 CC 1 4 in allen bolt 23 DD 1 4 in washer 11 EE 5 16 in washer 3 FF 5 16 in bolt 3 G...

Page 6: ...Upper Cylinder Chamber Wall Lower Cylinder Chamber Wall Lower Support Pole Upper Cylinder Chamber Door Lower Cylinder Chamber Door A B C D E F G H I J K L M N O Quantity 1 6 1 1 1 1 1 1 Part I J K L M...

Page 7: ...rall Width Heater Heat Input Qn Heater Gas Consumption Heater Injector Size Setting Pressure Regulator Outlet Pressure Standard Gas Supply Pressure 93 5 in approx 124 lbs 38 5 in 48 000 Btu h 2 20 Lbs...

Page 8: ...amber supports B to the corresponding section on the base A with the 6 pre fitted bolts Finger tighten only at this stage 2 Attaching the cylinder chamber walls Using 11 of the bolts AA and nuts BB at...

Page 9: ...ing six bolts CC and nuts BB At this point ensure that all bolts are tightened securely using a spanner 4 Attaching the cylinder chamber door Attach the upper cylinder chamber door panel G to the lowe...

Page 10: ...rts B using three bolts CC and three washers DD Attach the upper support pole J to the lower support pole F using four bolts CC four washers DD and four spring washers GG 6 Attaching the lantern Feed...

Page 11: ...the regulator L onto the gas cylinder turn clockwise to tighten it securely Position the gas cylinder inside the cylinder chamber as shown securing with the chain Perform a Leak Test see page 15 8 Fit...

Page 12: ...he top of the assembled side panels O using six bolts AA and nuts BB and then fully tighten all bolts O WARNING While every precaution has been made in the manufacture of this product care must be tak...

Page 13: ...ylinder to be used must be a Constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for cylinders Spheres and Tub...

Page 14: ...ncludes an overhead cover and three side walls as long as 30 or more of the horizontal periphery of the enclosure is permanently open LIGHTING INSTRUCTIONS Turn on the gas supply at the cylinder Push...

Page 15: ...Please contact the helpline stated in this manual Leak test annually and whenever the gas bottle is removed or replaced GAS AND REGULATOR The gas hose must be connected in accordance with these instr...

Page 16: ...lector The heater should never be operated without the reflector in place If the heater is to be stored indoors the gas bottle must be disconnected and left outside in a dry well ventilated area away...

Page 17: ......

Page 18: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Reviews: