LEAK TESTING

Your patio heater has been checked at all factory connections for leakage. To check the connection at the gas hose/regulator/cylinder:

 

Ensure you are in a well ventilated area.

 

Confirm all control knobs are in the off position.

 

Open the gas control valve on the bottle.

 

Check for leaks by brushing a solution of 50% water and 50% dish soap over the gas system joints, including all valve connections, 
hose connections and regulator connections.

 

NEVER USE AN OPEN FLAME to test for leaks at any time.

 

If bubbles form over any of the joints, there is a leak.

 

Turn off the gas supply and retighten all joints.

 

Repeat test. If bubbles form again, do not use the patio heater. Please contact the helpline stated in this manual.

 

Leak test annually and whenever the gas bottle is removed or replaced.

GAS AND REGULATOR

 

The gas hose must be connected in accordance with these instructions. When installed correctly all parts of the hose should be 
contained within the patio heater pole and gas cylinder chamber. No part of the hose should be outside of the patio heater body 
where it could be a trip hazard or could be accidently damaged.

 

This appliance is for propane use only.

 

See instructions supplied with the regulator for correct use and attachment.

 

Gas bottles should never be stored on their side.

 

Never store gas bottles indoors.

 

This appliance is supplied with a propane regulator which must only be used for propane gas.

 

NEVER use an adjustable regulator with this appliance.

 

Please consult your gas dealer for the most suitable gas bottles for your regulator.

Operation (continued)

Hose/Regulator

Regulator/Cylinder 
valve

Summary of Contents for 1002693243

Page 1: ...s online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay USE AND CARE GUIDE 48 000 COMMERCIAL GRADE HEAT FOCUSING PATIO HEATER Questions p...

Page 2: ...damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING NEVER use indoors in an enclosed area or below ground level WARNING...

Page 3: ...atio heaters WARNING Ensure the heater is at a safe distance from glass and PVC doors and windows to stop damage from any heat build up WARNING Read the warnings and use instructions before operation...

Page 4: ...r s receipt WHAT IS NOT COVERED Defects or damage caused by the use of other genuine parts are not covered by this warranty This warranty is valid for the original customer only and excludes product d...

Page 5: ...CLUDED NOTE Hardware not shown to actual size Part Description Quantity AA 1 4 in dome head bolt 32 BB 1 4 in nut 44 CC 1 4 in allen bolt 23 DD 1 4 in washer 11 EE 5 16 in washer 3 FF 5 16 in bolt 3 G...

Page 6: ...Upper Cylinder Chamber Wall Lower Cylinder Chamber Wall Lower Support Pole Upper Cylinder Chamber Door Lower Cylinder Chamber Door A B C D E F G H I J K L M N O Quantity 1 6 1 1 1 1 1 1 Part I J K L M...

Page 7: ...rall Width Heater Heat Input Qn Heater Gas Consumption Heater Injector Size Setting Pressure Regulator Outlet Pressure Standard Gas Supply Pressure 93 5 in approx 124 lbs 38 5 in 48 000 Btu h 2 20 Lbs...

Page 8: ...amber supports B to the corresponding section on the base A with the 6 pre fitted bolts Finger tighten only at this stage 2 Attaching the cylinder chamber walls Using 11 of the bolts AA and nuts BB at...

Page 9: ...ing six bolts CC and nuts BB At this point ensure that all bolts are tightened securely using a spanner 4 Attaching the cylinder chamber door Attach the upper cylinder chamber door panel G to the lowe...

Page 10: ...rts B using three bolts CC and three washers DD Attach the upper support pole J to the lower support pole F using four bolts CC four washers DD and four spring washers GG 6 Attaching the lantern Feed...

Page 11: ...the regulator L onto the gas cylinder turn clockwise to tighten it securely Position the gas cylinder inside the cylinder chamber as shown securing with the chain Perform a Leak Test see page 15 8 Fit...

Page 12: ...he top of the assembled side panels O using six bolts AA and nuts BB and then fully tighten all bolts O WARNING While every precaution has been made in the manufacture of this product care must be tak...

Page 13: ...ylinder to be used must be a Constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for cylinders Spheres and Tub...

Page 14: ...ncludes an overhead cover and three side walls as long as 30 or more of the horizontal periphery of the enclosure is permanently open LIGHTING INSTRUCTIONS Turn on the gas supply at the cylinder Push...

Page 15: ...Please contact the helpline stated in this manual Leak test annually and whenever the gas bottle is removed or replaced GAS AND REGULATOR The gas hose must be connected in accordance with these instr...

Page 16: ...lector The heater should never be operated without the reflector in place If the heater is to be stored indoors the gas bottle must be disconnected and left outside in a dry well ventilated area away...

Page 17: ......

Page 18: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Reviews: