Document #101-0008
6
11/11/05
III. STACKER REMOVAL
Front Load Cabinet
First, disconnect the Main Validator Harness. Next, disconnect the Stacker Wiring Harness by gently pulling
the connector apart. Remove the Validator and the Validator Support Bracket. Then remove the lower screw
holding the Stacker to the rear of the cabinet. Lift the Stacker approximately
1
/
2
" and pull forward. To continue
operating the changer without the Stacker, attach the Stacker By-pass Plug. (Refer to APPENDIX B for
instructions.)
Rear Load Cabinet
Lift the Stacker slightly to allow the Stacker pins to clear the Validator Support Bracket. Bring the Stacker
straight out of the cabinet until there is room to disconnect the wiring harness that runs from the Stacker to the
Controller. To continue operating the changer without the Stacker, attach the Stacker By-pass Plug. (Refer to
APPENDIX B for instructions.)