4
ACT2000 USER GUIDE
Certifications
North American Certifications
CSA Class I, Div 1, Group B, C, D; T4
European Directive Compliance (CE Mark)
EEx d, IIB+H
2
; T4
94/9/EC Potentially Explosive Atmospheres (ATEX) 08 ATEX 6108 X
(replaces 02ATEX6050X)
98/37/EC Machinery Directive
89/336/EEC Electromagnetic Compatibility Directive (EMC)
Materials
Housing
6061-T6 Anodized Aluminum
Conduit Union
Zinc Plated Steel
Extension Rod
17-4 PH CRES
Clevis
17-4 PH CRES
Seals
Nitrile, RTV and Teflon
Rod End Bearings
Aluminum Bronze
Connectors
Aluminum
Dimensions
5.2 in x 6.5 in x 16.7 in (ACT2000-590P)
6.0 in x 10.0 in x 12.9 in (ACT2000-200F)
Weight
35 lbs (ACT2000-590P)
50 lbs (ACT2000-200F)
1.3 Mechanical Installation
This section describes proper ACT2000 installation. Ensure compliance
with the factory recommendations.
Dimensions
The ACT2000 can be mounted with any directional orientation, whether
horizontal, vertical, or at an angle. Figures 1-1 and 1-3 show external
dimensions and mounting provisions for the pin-mount version of the
ACT2000. Figures 1-2 and 1-4 show external dimensions and mounting
provisions for the flange-mount version. Ensure that additional swing
clearance is factored into mounting calculations, as required.
WARNING
Lifting Hazard – Do not attempt to hand-lift the actuator. Use
appropriate lifting equipment.
Summary of Contents for Precision ACT2000 Series
Page 13: ...Figure 1 1 ACT2000 590P Dimensions INSTALLING THE ACT2000 7...
Page 14: ...8 ACT2000 USER GUIDE Figure 1 2 ACT2000 200F Dimensions...
Page 15: ...Figure 1 3 ACT2000 590P Pin Mounting Provisions INSTALLING THE ACT2000 9...
Page 16: ...10 ACT2000 USER GUIDE Figure 1 4 ACT2000 200F Flange Mounting Provisions...
Page 29: ...Figure 2 1 ACT2000 Electronics System Block Diagram CH 2 UNDERSTANDING THE ACT2000 23...
Page 34: ...28 ACT2000 USER GUIDE Figure 2 2 ACT2000 590P Cut Away View...
Page 37: ...Figure 2 5 Typical Refurbishment Plate CH 2 UNDERSTANDING THE ACT2000 31...
Page 38: ...32 ACT2000 USER GUIDE INTENTIONALLY BLANK...
Page 41: ...Figure 3 1 ACT2000 Basic Operation Flow Chart CH 3 OPERATING THE ACT2000 35...
Page 52: ...46 ACT2000 USER GUIDE INTENTIONALLY BLANK...
Page 54: ...48 ACT2000 USER GUIDE INTENTIONALLY BLANK...
Page 60: ...54 ACT2000 USER GUIDE INTENTIONALLY BLANK...