Figure 1: Furnace Dimensions 

 

Models

ALL

ALL

ALL

ALL

Input kW

10

12

15

20

With "A" Coil

NO

NO

NO

NO

Air Temperature Range - 

°

F

40-100

40-100

40-100

40-100

Max Outlet Air Temperature

180

180

185

185

Blower Size
Max. External Static Pressure In W.C.
Thernostat Circuit
Air Handler Cabinet Height

0.3

10 x 9

24 VAC, 60 HZ, 40 VA

33 Inches

 

Table 1: Electric Furnace Model Specifications 

 

Available Blower Motors 

1.

 

Standard Blower Motor - 5 SPD Constant Torque 

 

E = Mobile Home

Configuration

D = Dow nflow

4 = 1/2 HP

020 = 20 kW Electric Heater

015 = 15 kW Electric Heater

012 = 12 kW Electric Heater

010 = 10 kW Electric Heater

B = Constant Torque

Electric Heat

W = Winchaster

Discharge

Heat Strip kW

Horse Power

Blow er Motor

of Motor

Type

of Heat

Type

Name

Product

Single Stage

Heating

30

 

Table 2: Furnace Model Nomenclature 

 

Coil

 

Cabinet

 

Model

Front

 

Door

 

of

 

Cabinet

Open

 

Top

 

17

 

3/4"

 

x

 

21

 

3/4"

Maximum

 

Air

 

Flow

 

CFM

1"

 

Pleated

 

Air

 

Filter,

 

In

 

The

 

Door

2"

 

Pleated

 

Air

 

Filter,

 

Top

 

of

 

Cabinet

Height Depth Width

97

FLSB

21

Louvered

N/A

1200

20x20

23

 

1/4"

25"

19

 

3/4"

97

FSOB

21

Solid

1600

20x24

23

 

1/4"

25"

19

 

3/4"

97

FLOB

21

Louvered

1800

20x20

20x24

23

 

1/4"

25"

19

 

3/4"

97

FLSB

27

Louvered

N/A

1600

20x30

30

 

1/2"

25"

19

 

3/4"

97

FSOB

27

Solid

1600

20x24

30

 

1/2"

25"

19

 

3/4"

97

FLOB

27

Louvered

1800

20x20

20x24

30

 

1/2"

25"

19

 

3/4"

97

FLSB

39

Louvered

N/A

1800

2ea

 

20x20

40

 

1/4"

25"

19

 

3/4"

97

FSOB

39

Solid

2000

20x24

40

 

1/4"

25"

19

 

3/4"

97

FG

18

Louvered

N/A

1200

N/A

N/A

18"

N/A

19

 

3/4"

97

FG

24

Louvered

N/A

1600

N/A

N/A

24"

N/A

19

 

3/4"

Frame

 

&

 

Grills

 

Non

Cabinet

Coil

 

Sizes

All

 

Mortex

 

96

 

series

 

coils

 

will

 

fit

 

in

 

cabinet

 

96

97

 

series

 

coils

 

and

 

98

 

series

 

coils

 

sizes

 

up

 

to

 

98

8W7

All

 

Mortex

 

series

 

coils

 

will

 

fit

 

in

 

cabinet

 

Table 3: Optional Cooling Cabinets and Return Air Grille Frame Assemblies 

Summary of Contents for WE30 Series

Page 1: ...er Location 11 29 Wiring Diagram 20 kW w C T Blower Motor 22 15 Control Box Power Low Voltage Wire Locations 13 LIST OF TABLES 1 Electric Furnace Model Specifications 2 8 Electrical Data 10 2 Model No...

Page 2: ...Single Stage Heating 30 Table 2 Furnace Model Nomenclature Coil Cabinet Model Front Door of Cabinet Open Top 17 3 4 x 21 3 4 Maximum Air Flow CFM 1 Pleated Air Filter In The Door 2 Pleated Air Filter...

Page 3: ...ce heating cooling equipment Untrained service personnel can perform basic maintenance functions such as cleaning of exterior surfaces and replacing the air filters Observe all precautions in the manu...

Page 4: ...y a closet or alcove must have a certain total free area opening for the return air For A C and HP Furnaces 1 3 HP Blower Minimum 200 in free area opening Use Return Grille or Coil Cabinet For A C and...

Page 5: ...to use SECTION IV SUPPLY AIR AND DUCT CONNECTOR INSTALLATION Duct Connectors 90 DCU0 XX Duct Connectors The duct connector is used to provide a sealed connection between the furnace base and a under...

Page 6: ...the insulation around the perimeter of the duct connector opening 5 Install the floor base over the floor opening with the flanges on the 11 x 13 inch opening facing down Refer to Figures 8 and 9 6 Lo...

Page 7: ...to the floor by drilling two holes through the furnace base and the floor base at the right and left front inside corners of the cabinet Use two screws to secure the furnace to the floor Figure 10 Re...

Page 8: ...e coil cabinet 11 Place the cooling cabinet front door on the unit by inserting the tabs in the bottom of the door into the slots in the coil shelf line up the strike in the front flange of the top co...

Page 9: ...Electrical Code Part I CSA C22 1 and local codes for additional requirements concerning supply circuit wiring Electrical data can be found in Tables 6 7 and 8 IMPORTANT All installation on field wiri...

Page 10: ...er supply will require circuit breaker jumper bar or a jumper wire Refer to the National Electrical Code Table 250 95 for Non Sheathed Conductor Ground Wire Ground conductor must be the same size and...

Page 11: ...le codes Figure 14 Control Box Cover and Circuit Breaker Location Dual Element Box For personal safety be sure to turn the electrical power OFF at the main circuit panel Home Circuit Breaker Box and a...

Page 12: ...cated on the blower housing 6 Follow the instructions in the USERS INFORMATION MANUAL to properly start up the air handler POWER SUPPLY CONNECTIONS If the air handler has been installed prior to insta...

Page 13: ...Installation The thermostat heat anticipator must be set at 0 7 Amps if the thermostat has a manual heat anticipator adjustment This setting should be checked at the time of installation The thermost...

Page 14: ...R Figure 16 Separate Thermostats Separate Air handler and Cooling Unit G R W R G Y Heating Thermostat Cooling Thermostat C Y R G W C COM HEAT COOL Thermostat Interlock Switch Air Handler 24 VAC Transf...

Page 15: ...8 strain relief in the control box and place the thermostat wire cable next to the low voltage terminal block 6 Connect the Red 24 VAC supply thermostat wire to the red pigtail wire and secure the two...

Page 16: ...peratureSwitch W2 J u m p e r Figure 22 Typical Heat Pump 2 Stage Heating Cooling Connections SECTION X MOTOR BLOWER AND FURNACE START UP Selecting the Constant Torque Blower Speed This furnace uses t...

Page 17: ...s to the furnace at the main circuit panel House Circuit Breaker 14 Set the thermostat to the desired temperature Figure 24 Blower Assembly and Blower Deck SECTION XI FINAL SYSTEM CHECKOUT 1 Refer to...

Page 18: ...BLK W H T G R N Y E L L2 B L K WHT B LU B L K BM G R N GGS Y E L C L A S S 2 CLASS 2 CC COMPRESSOR CONTACTOR RVS REVERSING VALVE SOLENOID LEGEND TB TERMINAL BLOCK BMFP 6 PIN MOLEX BLOWER MOTOR PLUG A...

Page 19: ...L1 HC1 T2 L2 G R N GGS C L A S S 2 WHT W H T WHT CLASS 2 CC COMPRESSOR CONTACTOR RVS REVERSING VALVE SOLENOID LEGEND TR TRANSFORMER BMFP 6 PIN MOLEX BLOWER MOTOR PLUG ASSEMBLY GND GROUND CONNECTION B...

Page 20: ...N B R N BRN BLK WHT BLK BLK THERMOSTAT W2 BLK BLK BLK BLK B L K B L K B R N BRN B R N BRN B R N HPM 7 RED ST1 8 BLK L1 9 BLU ST4 Y E L L 2 G R N G N D P R P S T 3 B L K S T 5 B R N 2 4 V C O M BRN G N...

Page 21: ...40 VAC 24 VAC BLK 1 BLK SUPPLY WIRING XMC0 402EBBC Contactor L1 T1 L2 T2 HC1 BLU BLU L1 GND G BLK WHT G R N R E D HC1 HTR1 BLK BLU RED RED T1 C B L1 C irc u it 1 L2 C B C irc u it 1 B L K HC1 T2 L2 1...

Page 22: ...BRN BLU GND BLU PRR ST3 ORN ST2 B R N 2 4 V C O M B L U S T 4 O R N S T 2 P R P S T 3 B L U O R N P U R B L U B L U W H T W B R N BLU B L U B L K B L K R E D R E D FOR A TWO STAGE HEATING THERMOSTAT R...

Reviews: