ENG-FRM-RIC-4.32, Rev. E
Technical Data Sheet
HBH550
PROPRIETARY RIGHTS NOTICE
This document and all information contained within it is the property of Hamilton Beach Brands, Inc. (HBB). It is confidential and
proprietary and has been provided to you for a limited purpose. It must be returned or destroyed upon request. Disclosure, reproduction or use of this document
and any information contained within it, in full or in part, for any purpose is forbidden without the prior written consent of HBB. No photographs may be taken of any
article fabricated or assembled from this document without the prior written consent of HBB.
Replacing the Vacuum Chamber Interlock Switches:
1. Turn the unit upside down then remove the 8 Phillips head screws.
2. Return the unit to right side up.
3. Carefully lift the Vacuum chamber out of the housing then turn it upside down to expose the
interlock switches.
4. Press the tabs on the side of the switch housing to release, then push the switches through the housing.
5. Install New switches then reassemble the unit in reverse order.
PCB Layout:
4421 Waterfront Drive
Glen Allen, VA 23060
Revision Description:
Request Number:
Revision Date:
Approved by:
Issue Code(s):
Page:
6
of
6
Document #:
Rev: